Key Features

  •  Simultaneous Power & Power quality measurements
  •  Helpful support functions
  •  Measurement with high accuracy
  •  Remote monitoring on PC and Android device
  •  Various Clamp Current Sensors
  •  Energy consumption check on site
  •  IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V

SPECIFICATIONS KYORITSU 6315 POWER QUALITY ANALYZER

Wiring connections: 1P2W, 1P3W, 3P3W, 3P4W

Measurements and parameters 

Voltage, Current, Frequency, Active power, Reactive power, Apparent power,Active energy, Reactive energy, Apparent energy, Power factor (cos θ),
Neutral current, Demand, Harmonics, Quality (Swell/Dip/Interruption, Transients/Over voltage, Inrush current, Unbalance rate),
Capacitance calculation for PF correction unit, Flicker

Voltage (RMS)

Range: 600.0 / 1000V
Accuracy: ±0.2%rdg±0.2%f.s. (sine wave, 40 – 70Hz)
Allowable input: 1 – 120% of each range (rms). 200% of each range (peak)
Display range: 0.15 – 130% of each range
Crest factor: 3 or less
Sampling speed of Voltage transient: 24µs
Current (RMS)

Range:
8128 ( 50A type ) : 5000mA / 50.00A / AUTO
8127 ( 100A type ) : 10.00 / 100.0A / AUTO
8126 ( 200A type ) : 20.00 / 200.0A / AUTO
8125 ( 500A type ) : 50.00 / 500.0A / AUTO
8124/8130 ( 1000A type ) : 100.0 / 1000A / AUTO
8146/8147/8148 ( 10A type ) : 1000mA / 10.00A / AUTO
8133 ( 3000A type ) : 300.0 / 3000A / auto
Accuracy: ±0.2%rdg±0.2%f.s. + accuracy of clamp sensor (sine wave, 40 – 70Hz)
Allowable input: 1 – 110% of each range (rms). 200% of each range (peak)
Display range: 0.15 – 130% of each range
Crest factor: 3 or less
Active power

Accuracy: ±0.3%rdg±0.2%f.s. + accuracy of clamp sensor (power factor 1, sine wave, 40 – 70Hz)
Influence of power factor: ±1.0%rdg (reading at power factor 0.5 against power factor 1)
Frequency meter range: 40 – 70Hz
Power supply (AC Line): AC100 – 240V / 50 – 60Hz / 7VA max
Power supply (DC battery):
Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6
Battery life approx. 3h (LR6, Backlight OFF)
Internal memory: FLASH memory (4MB)
PC card interface: SD card (2GB)
PC communication interface: USB Ver2.0, Bluetooth Ver2.1 + EDR Class2
Display: 320 × 240 (RGB) Pixel, 3.5inch color TFT display
Display update period: 1 sec

  • General

Applicable standards:

IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V Pollution degree 2
IEC 61010-2-030, IEC 61010-031, IEC 61326, EN 50160
IEC 61000-4-30 Class S, IEC 61000-4-15, IEC 61000-4-7

Temperature and humidity range: 23±5ºC, less than 85% RH (without condensation)

Operating temperature & humidity range: 0 – +45ºC, less than 85% RH (without condensation)

Storage temperature & humidity range: -20 – +60ºC, less than 85% RH (without condensation)

Power supply (AC Line): AC100 – 240V / 50 – 60Hz / 7VA max

Power supply (DC battery)

Alcaline size AA battery LR6 or Ni-MH (HR-15-51) × 6
Battery life approx. 3h (LR6, Backlight OFF)

Dimensions: 175(L) × 120(W) × 68(D) mm

Weight: Approx. 900g

Included Accessories

7141B (Voltage test lead)
7170 (Power cord)
7219 (USB cable)
8326-02 (SD card 2GB)
9125 (Carrying case for KEW 6315, KEW 6315-01)
9135 (Carrying case for KEW 6315-03, KEW 6315-04, KEW 6315-05)
Input terminal plate × 6, KEW Windows for KEW 6315 (software),
Quick manual, Alkaline size AA battery (LR6) × 6

Optional Accessories

8124, 8125, 8126, 8127, 8128 (Load current clamp sensor)
8130, 8133 (Flexible clamp sensor)
8146, 8147, 8148 (Leakage and Load current clamp sensor)
8312 (Power supply adaptor)
9132 (Magnetc carrying case)

Introduction Kyoritsu 6315

The Kyoritsu 6315 Power Analyzer Measures voltage swells/dips/interruptions/transients and inrush currents that may indicate a weak power distribution system. Such phenomena may damage or reset devices. KEW 6315 can catch swells/dips/interruptions and inrush currents based on half cycle (10 ms @ 50Hz or 8.3ms @ 60Hz) TRMS.

All necessary data is displayed by pressing one key. The Kyoritsu 6315 can safely measure currents of up to 3000A. As well as the performance analysis, the Kyoritsu 6315 can execute a complete network analysis. The Power Analyzer also measures the phase angle, harmonics, apparent power, active power, & work.

– Simultaneous Power & Power quality measurements

    • Power/ Harmonics/ Waveform/ Power quality are recorded at all CHs. (Voltage: 3ch, Current 4ch)

– Helpful support functions

    • Quick Start Guide, Wiring check and Sensor detection for easy and reliable measurement

– Measurement with high accuracy

    • Guaranteed accuracy:±0.3%rdg (energy),±0.2%rdg (voltage/ current)
      Complies with the International Standard IEC 61000-4-30 Class S and the European Standard EN50160

– Remote monitoring on PC and Android device

    • Remote checking of measurement in real-time is possible via Bluetooth communication.
    • Recorded data can be saved in the supplied SD card.
    • EN50160 report can be generated after survey by PC software.

– Various Clamp Current Sensors

    • Various types of clamp and flexible sensors are available:
      from 1000mA Range up to 3000A Range and Earth leakage measurements
    • Energy consumption check on site
      Trend and demand graphs for easy recognition.
      TFT color display with high resolution.

– IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V

Features

– Simultaneous Power & Power quality measurements
– Helpful support functions
– Measurement with high accuracy
– Remote monitoring on PC and Android device
– Various Clamp Current Sensors
– Energy consumption check on site
– IEC 61010-1 CAT IV 300V, CAT III 600V, CAT II 1000V

Attribute

Brand

Review KYORITSU 6315 POWER QUALITY ANALYZER

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review KYORITSU 6315 POWER QUALITY ANALYZER
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    RECENT PRODUCT

    hotline techmaster
    Hotline: 0936 532 379
    zalo techmaster Zalo: 0936 532 379 messenger techmaster Nhắn tin Facebook email techmaster Gửi Mail
    support techmaster