SPECIFICATIONS GRAPHTEC midi LOGGER GL240
Number of analog input channels | 10 channels | |
External input/ output *1 |
Input *2 | Trigger or Sampling (1 channel), Logic/Pulse (4 channels) |
Output *3 | Alarm (4 channels) | |
Sampling interval | 10 ms to 1 hour (10ms to 50ms: voltage only) *4, External signal | |
Time scale of waveform display | 1sec. to 24 hour /division | |
Trigger, Alarm function |
Trigger action | Start or stop capturing data by the trigger |
Repeat action | Off, On (auto rearmed) | |
Trigger source | Start: Off, Measured signal, Alarm, External, Clock, Week or Time Stop: Off, Measured signal, Alarm, External, Clock, Week or Time |
|
Condition Setting | Combination: OR or AND Analog signal: Rising (High), Falling (Low), Window-in, Window-out Logic signal: Pattern (combination of each input signal in high or low) Pulse (number of count): Rising (High), Falling (Low), Window-in, Window-out |
|
Alarm output | Outputs a signal when alarm condition occurs in the input signal *5 | |
Pulse input function |
Rotation count (RPM) |
Counts the number of pulses per sampling interval and converts to rpm (rotations per minute), Number of pulses for one rotation may be set to 50, 500, 5000, 50k, 500k, 5M, 50M, 500M rpm/F.S. (rpm./Full Scale) |
Accumulating count |
Accumulates the number of pulses from the start of measurement 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/Full Scale) |
|
Instant count | Counts the number of pulses per sampling interval 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/Full Scale) |
|
Maximum number of pulse inputs | Maximum input frequency : 50kHz Maximum number of count : 50kC/sampling (16-bit counter) |
|
Calculation function |
Between channels | Addition, Subtraction, Multiplication, and Division for analog input |
Statistical | Select two calculations from Average, Peak, Maximum, Minimum, RMS | |
Search function | Search for analog signal levels, values of logic or pulse or alarm point in captured data |
|
Interface to PC | USB (Hi-speed), WLAN (using B-568 option) | |
Storage device |
Internal | Built-in 4GB Flash Memory *6 |
External | One SD card slot (Support SDHC memory card, up to 32GB) *7 | |
Saved contents | Captured data, Setting conditions, Screen copy | |
Back up recording data function | Backup interval *8 | Off, 1, 2, 6, 12, 24 hour(s) |
Backup file destination *8 | SD memory card or FTP server | |
Data format *8 | GBD (binary) or CSV (test) | |
Check-sum function (Verifies data file) | OFF: Not adding check-sum code to data file. ON: Adding check-sum code to data file. Check-sum code is verified when replaying data on the GL unit or GL-Connection software. |
|
Capturing mode | Mode: Normal, Ring, Relay Ring: Saves most recent data (Number of captured data: 1000 to 2000000 points) *9 Relay: Saves data to multiple files without losing data until data capturing is stopped |
|
Replay Data | Replays captured data that was saved in the GL240 (in GBD or CSV format) | |
Scaling (Engineering unit) function | Measured value can be converted to the specified engineering unit • Analog voltage: Converts using four reference points (gain, offset) • Temperature: Converts using two reference points (offset) • Pulse count: Converts using two reference points (gain) |
|
Action during data capture | • Displaying parst data (using dual display mode (Current + Past data)) • Hot-swapping the SD memory card • Saving data in between cursors |
|
Display | Size | 4.3-inch TFT color LCD (WQVGA: 480 x 272 dots) |
Language | English, French, German, Chinese, Korean, Russian, Spanish, Japanese | |
Information *10 | Waveform in Y-T with digital values, Waveform only, Digital value, Digital values and statistics values |
|
Operating environment | 0 to 45 ºC, 5 to 85 % RH (non condensed) (When operating with battery pack 0 to 40 ºC, charging battery 15 to 35 ºC) |
|
Power source | AC adapter | 100 to 240 V AC, 50/60 Hz (1 pc of adapter is attached as standard accessory) |
DC power | 8.5 to 24 V DC (DC drive cable (option B-514) is required) | |
Battery pack | Mountable battery pack (battery pack (option B-569): 7.2V DC, 2900mAh) | |
Power consumption *11 | Max. 36 VA | |
External dimensions (W x D x H in mm, Excluding projections) |
Approx.194 x 121 x 46 (with the cover) | |
Weight *12 | Approx. 634 g (the cover is attached) |
*1Input/Output cable for GL (option B-513) is required to connect the signal.*2Input signal;
- Voltage range: Up to 24V (common ground)
- Signal type: Voltage, Open collector, Contact (relay)
- Threshold: Approx. + 2.5 V (Hysteresis: Approx. 0.5V (2.5V to 3V))
*3Output signal: Open collector (pull-up to 5V by 10kΩ resistor)
<Maximum rating of the output transistor>
- Voltage: Max. 30V
- Current: Max. 0.5A
- Collector dissipation: Max. 0.2W
*4Minimum interval varies by number of channels used.*5Output port can be specified in each input channel.*6The built-in Flash memory is available for units with serial numbers C6043XXX or later. Please contact your local representative for more information.*7SD memory card cannot be used on SD card slot while the wireless LAN unit (opton B-568) is used.*8The CSV format is available with firmware version 1.43 or rater.
– When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available.
– When there are meany number of active channels, the sampling time is fast, or the backup interval is long, it may take time to closing the data file after recording stops because the size of the data to be backed up becomes large.
– When saving file to FTP server using wireless LAN connection, backup may fail depending on the communication condition.
– Available sampling speed is the 100 ms or slower when using the CSV format.
– When backup is enabled and data file format is specified with CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.*9Size of the capture data will be limited to 1/3 of available memory.*10Display mode is switched every time the dedicated key is pressed. In magnified digital value mode, the displayed channel number can be specified. In the waveform display mode, the changing of the time scale will be effective from the point of the next displayed data.*11Rating under maximum power consumption using the AC adapter, with LCD display on, and battery pack being
charged.*12Excludes AC adapter and battery pack.
Introduction Graphtec midi LOGGER GL240
The Graphtec midi LOGGER GL240 is a versatile data acquisition instrument designed for recording and analyzing various types of data in real-time. It’s a part of Graphtec’s line of data loggers and is commonly used in research, industrial, and scientific applications where precise data collection is essential. The GL240 is known for its reliability, user-friendly interface, and the ability to handle a wide range of input signals.
The midi LOGGER GL240 offers multiple input channels, allowing you to simultaneously record data from various sources. These sources can include voltage, temperature, humidity, pulse, and more, depending on the type of sensor or signal you’re using. The compact and portable design of the GL240 makes it easy to transport and set up for data collection in different environments. This portability is especially useful for fieldwork or when you need to move the logger between different locations.
The device features a built-in touchscreen display that provides an intuitive interface for configuring settings, monitoring data in real-time, and reviewing recorded data directly on the device. The midi LOGGER GL240 supports high data sampling rates, which allows it to capture rapid changes in signals with precision. This is particularly important for applications where fast changes need to be accurately recorded. The device comes with internal memory for data storage. Additionally, it typically supports external storage options such as SD cards or USB drives, which means you can store a large amount of data without worrying about running out of space.
Graphtec usually provides software that accompanies the GL240, allowing you to easily transfer recorded data to a computer for more in-depth analysis. This software often includes tools for graphing, analyzing, and exporting the data.
Features
- Wireless measurement using wireless LAN (option)
>Wireless LAN option enables the wireless communication with other device.When the GL240 is set as a station, PC and smart devices will be able to access the WLAN unit directly. - Combining GL100-WL and GL240
>GL100-WL cab now be connected to the GL240 as a remote sensor using the WLAN feature.GL240 supports 1 unit of the GL100-WL. - All channel isolated/Universal input, Standalone Multi-Channel
>Its compact size contains an isolated input system which ensures that signals are not corrupted by inputs to other channels. - Maximum sampling interval of up to 10ms
>Provides faster sampling rate 10ms for voltage measurement. - Built-in 4GB Flash memory with SD card support
>The new GL series enables reliable long term measurment with its built-in 4GB flash memory and SD card slot for external storage devices.
Review Graphtec midi LOGGER GL240
There are no reviews yet.