SPECIFICATIONS: KYORITSU 4106 EARTH RESISTANCE & RESISTIVITY TESTER
Earth resistance Re (Rg at ρ measurement)
+ Range: 2Ω
Resolution: 0.001Ω
Measuring range: 0.03 – 2.099Ω
Accuracy: ±2%rdg±0.03Ω
+ Range: 20Ω
Resolution: 0.01Ω
Measuring range:0.03 – 20.99Ω
Accuracy: ±2%rdg±5dgt (*1)
+ Range: 200Ω
Resolution: 0.1Ω
Measuring range: 0.3 – 209.9Ω
Accuracy: ±2%rdg±5dgt (*1)
+ Range: 2000Ω
Resolution: 1Ω
Measuring range: 3 – 2099Ω
Accuracy: ±2%rdg±5dgt (*1)
+ Range: 20kΩ
Resolution: 10Ω
Measuring range: 0.03k – 20.99kΩ
Accuracy: ±2%rdg±5dgt (*1)
+ Range: 200kΩ
Resolution: 100Ω
Measuring range: 0.3k – 209.9kΩ
Accuracy: ±2%rdg±5dgt (*1)
Auxiliary earth resistance Rh, Rs: 8% of Re+Rh+Rs
Earth resistivity ρ
+ Range: 2Ω
Resolution: 0.1Ω·mm – 1Ω·m Autoranging
Measuring range: 0.2 – 395.6Ω·m
Accuracy: ρ=2×π×a×Rg (*2)
+ Range: 20Ω
Resolution: 0.1Ω·mm – 1Ω·m Autoranging
Measuring range: 0.2 – 3956Ω·m
Accuracy: ρ=2×π×a×Rg (*2)
+ Range: 200Ω
Resolution: 0.1Ω·mm – 1Ω·m Autoranging
Measuring range: 20 – 39.56kΩ·m
Accuracy: ρ=2×π×a×Rg (*2)
+ Range: 2000Ω
Resolution: 0.1Ω·mm – 1Ω·m Autoranging
Measuring range: 0.2 – 395.6kΩ·m
Accuracy: ρ=2×π×a×Rg (*2)
+ Range: 20kΩ
Resolution: 0.1Ω·mm – 1Ω·m Autoranging
Measuring range: 2.0 – 1999kΩ·m
Accuracy: ρ=2×π×a×Rg (*2)
+ Range: 200kΩ
Resolution: 0.1Ω·mm – 1Ω·m Autoranging
Measuring range: 2.0 – 1999kΩ·m
Accuracy: ρ=2×π×a×Rg (*2)
Series interference voltage Ust (A.C only) (*3)
+ Range: 50V
Resolution: 0.1V
Measuring range: 0 – 50.9Vrms
Accuracy:
±2%rdg±2dgt (50/60Hz)
±3%rdg±2dgt (40 – 500Hz)
Frequency Fst
+ Range:Autoranging
Resolution:
0.1Hz
1Hz
Measuring range: 40Hz – 500Hz
Accuracy: 40Hz – 500Hz
Measuring method:
Earth resistance: Fall-of-potential method (currents and voltages measured via the Probes)
Measurement method of Earth Resistivity (ρ): Wenner 4-pole method
Series interference voltage (earth voltage)
RMS Rectifier (between the E-S Terminals)
Memory capacity:
800 data
Communication Interface:
Model 8212-USB Optical Adaptor
LCD:
Dot-matrix 192×64 monochrome
Over-range Indication:
“OL”
Overload Protection:
between E-S(P) and between E-H(C) terminals AC280V / 10 sec.
Applicable standards:
IEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2
IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)
Power source:
DC12V : sizeAA manganese dry battery (R6) × 8 (Auto power off: approx. 5 minutes)
Dimensions:
167(L) × 185(W) × 89(D) mm
Weight: approx. 900g (including batteries)
Accessories:
229A (Earth precision measurement),
7238A (Simplified measurement test leads),
8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),
8200-04 (Cord reel [4 pcs])×1 set,
8212-USB (USB adaptor with “KEW Report(Software)”),
9121 (Shoulder strap),
9125 (Carrying case),
R6 × 8, Instruction manual, Calibration certificate
Optional:
8212-RS232C (RS232C adaptor with “KEW Report(Software)”)
(*1) Auxiliary earth resistance is 100Ω with Rk correction
(*2) Depending on the measured Rg. Interval [a] between auxiliary earth spikes is 1.0 – 30.0m
(*3) This instrument is NOT designed to measure line voltages on commercial powers.
Introduction Kyoritsu 4106
Kyoritsu KEW 4106 is a 2/ 3/ 4-wire digital earth resistance/earth resistivity tester, equipped with a microcomputer, for measuring earth resistances and calculating earth resistivities. It has an output voltage of 10 Vrms or lower. This makes it an instrument of choice for measuring earth resistances on installations ranging from in-house wiring systems and electrical appliances to power distribution lines. Sub-results that can be shown on the display include resistance of the auxiliary earth spikes, frequency of test current, voltage and frequency of interference (noise) and residual resistance Rk.
Features
• High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.
• Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
• Automatic and Manual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency.
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance.
• Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC using the “KEW Report” software and a USB adaptor (Model 8212-USB) which are included.
• Robust design with IP54 protection.
Review KYORITSU 4106 EARTH RESISTANCE & RESISTIVITY TESTER
There are no reviews yet.