Fluke T+ Electrical Tester
Product overview: Fluke T+ Electrical Tester
How to use the T+ Electrical Tester
The T+ Electrical tester offer three ways to know if AC/DC voltage is present. It lights up, makes a sound, and vibrates for added user protection. With these indicators, the user will be alerted to the presence of voltage even in dark, or noisy environments. The audible indicator can also be easily switched off – with the push of a button.
Part of the safety designed into the T+ Electrical Tester is that is can still detect live voltage even when the batteries are dead. It also holds a safety rating:
CAT IV 600 V, CAT III 1000 V
Fully compliant with NFPA 70E
GFCI Trip testing
The T+ tester has a GFCI Trip for testing GFCI circuits on outlets. A built-in flashlight also lets the user highlight the test point being measured for easier visibility.
The back of the tester is also designed with convenient test lead storage. And all of that is backed by a 2-year warranty.
“This is my “go to” when I get a trouble call at work for industrial electrical trouble shooting.” – Winchester
What’s in the box:
- T+ Electrical Tester
- Test lead wrap
- TP2 test probes
- Quick Reference Guide
Specifications: Fluke T+ Electrical Tester
Specifications | ||
Temperature | Operating | -10°C to 55°C (14°F to 131°F) |
Storage | -30°C to 60°C (-22°F to 140°F) | |
Relative humidity | 90% | 0°C to 30°C (32°F to 86°F) |
75% | 30°C to 40°C (86°F to 104°F) | |
45% | 40°C to 50°C (104°F to 122°F) | |
Altitude | Operating | 2,000 m (approx. 6,561.6 ft) |
Storage | 10,000 m (approx. 32,808.4 ft) | |
Battery type/life | AAA (2); 40 hours | |
Shock, vibration | Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument | |
Safety | ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 – 1 to 1000 V CAT III/600 V CAT IV Compliance to NFPA 70E1 |
|
AC bandwidth | 45 Hz to 66 Hz | |
Maximum working voltage | 1000 V AC/DC | |
Maximum measurable voltage | 600 V AC/DC | |
Duty cycle | Indefinitely for voltages up to 240 V | |
For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off | ||
For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s | ||
Voltage hazard LED | LEDs turn on at voltages > 30 V AC/DC ± 35% | |
LED voltage indication levels | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V | |
LEDs | LEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100% | |
LCD resolution | 0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V | |
GFCI test current | 100 V – 150 V @ 6 mA – 9 mA AC, 150 V – 240 V < 12 mA | |
Standard input test current | < 5 mA | |
Size (H x W x L) | 1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm ) | |
Weight | 9.9 oz (0.28 kg) | |
1. When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment. |