MSOX3052G Keysight Oscilloscope

 

Features:

  • 500 MHz
  • 2 analog plus 16 digital channels
  • Easily view and analyze your signals with on the large 8.5-inch capacitive touch screen
  • Isolate signals in seconds with exclusive zone touch triggering
  • See more signal detail with the 1,000,000 wfms/s update rate
  • Capture more data with up to 4 Mpts memory
  • Expand your measurement capabilities with full upgradability: add bandwidth and advanced application software at any time

SPECIFICATIONS MSOX3052G Keysight Oscilloscope

General technical data:

Bandwidth: 500 MHz
Calculated rise time (10 to 90%): ≤ 700 ps
Input channels: 2 + 16
Maximum sample rate: 5 GSa/s half channels, 2.5 GSa/s all channels
Maximum memory depth: 4 Mpts half channels, 2 Mpts all channels
Display size and type: 8.5-inch capacitive touch gesture-enabled display
Waveform update rate: > 1,000,000 waveforms per second
Connectivity: Standard ports:
One USB 2.0 hi-speed device port on rear panel. Supports USBTMC protocol
Two USB 2.0 hi-speed host ports, front and rear panel. Support memory devices, printers, and keyboards
LAN (10/100Base-T)
WVGA video out
Optional ports: GPIB
Trigger out: BNC connector on the rear panel. Supported modes: triggers, mask, and waveform generator sync pulse

 

Vertical System Analog Channels:

Hardware bandwidth limits: Approximately 20 MHz (selectable)
Input coupling: AC, DC
Input impedance: Selectable: 1 MΩ ± 1% (14 pF), 50 Ω ± 1.5%
Input sensitivity range: 100 MHz ~ 500 MHz models: 1 mV/div to 5 V/div 2 (1 MΩ and 50 Ω)
1 GHz models: 1 mV/div to 5 V/div 2 (1 MΩ), 1 mV/div to 1 V/div (50 Ω)
Vertical resolution: 8 bits (measurement resolution is 12 bits with averaging)
Maximum input voltage: 125 Vrms; 190 Vpk

 

Horizontal System Analog Channels

Time base range: 1 ns/div to 50 s/div
Time base accuracy: ± 1.6 ppm + aging factor (1st year: ± 0.5 ppm, 2nd year: ± 0.7 ppm, 5 years: ± 1.5 ppm, 10 years: ± 2.0 ppm)
Time base delay time range: Pre-trigger: Greater of 1 screen width or 250 μs
Post-trigger: 1 s to 500 s
Channel-to-channel deskew range: ± 100 ns

 

Vertical System Digital Channels:

Digital input channels: 16 digital (D0 to D15. pod 1: D7 ~ D0, Pod 2: D15 ~ D8)
Ngưỡng đầu vào: Threshold per pod
Threshold selections: TTL (+1.4 V), 5 V CMOS (+2.5 V), ECL (–1.3 V), user-defined (selectable by pod)
Maximum input voltage: ± 40 V peak
Threshold accuracy: ± (100 mV + 3% of threshold setting)
Maximum input dynamic range: ± 10 V about threshold
Minimum voltage swing: 500 mVpp
Input impedance 100 kΩ ± 2% at probe tip
Input capacitance: ~8 pF
Vertical resolution: 1 bit

 

Horizontal System Digital Channels:

Minimum detectable pulse width: 5 ns
Channel-to-channel skew: 2 ns (typical); 3 ns (maximum)

 

Trigger System:

Trigger modes: Normal, Auto, Single, Force
Trigger coupling: DC, AC, HF reject, LF reject, Noise reject
Trigger holdoff range: 40 ns to 10.00 s

 

Digital Voltmeter (specifications are typical):

Functions: ACrms, DC, DCrms
Resolution: ACV/DCV: 3 digits
Measuring rate: 100 times/second

 

WaveGen – Built-in Function/Arbitrary Waveform Generator:

Waveforms: Sine, Square, Ramp, Pulse, DC, Noise, Sine Cardinal (Sinc), Exponential Rise, Exponential Fall, Cardiac, Gaussian Pulse, and Arbitrary
Sine: Frequency range: 0.1 Hz to 20 MHz
Square wave /pulse: Frequency range: 0.1 Hz to 10 MHz
Ramp/triangle wave: Frequency range: 0.1 Hz to 200 kHz
Noise: Bandwidth: 20 MHz typical
Frequency: Sine wave and ramp accuracy: 130 ppm (frequency < 10 kHz); 50 ppm (frequency > 10 kHz)
Square wave and pulse accuracy: [50+frequency/200] ppm (frequency < 25 kHz); 50 ppm (frequency ≥ 25 kHz)
Resolution: 0.1 Hz or 4 digits, whichever is larger
DC offset: Range: ± 2.5 V into Hi-Z; ± 1.25 V into 50 Ω
Resolution: 100 μV or 3 digits, whichever is higher
Accuracy (DC mode): ± 1.5% of offset setting ± 3 mV
Amplitude: Range: 20 mVpp to 5 Vpp into Hi-Z; 10 mVpp to 2.5 Vpp into 50 Ω
Accuracy: 2% (frequency = 1 kHz)

 

Waveform Math:

Arithmetic: Add, subtract, multiply, divide, differentiate, integrate, FFT, Ax + B, squared, square root, absolute value, common logarithm, natural logarithm, exponential, base 10 exponential, low pass filter, high pass filter, averaged value, smoothing, envelope, magnify, max hold, min hold, measurement trend, chart logic bus (Timing or State), chart serial signal (CAN, CAN FD, LIN, and SENT)
FFT: Record size: Up to 64 kpts resolution
Window: Hanning, flat top, rectangular
Time gated FFT: Gate the time range of data for FFT analysis in the zoom view. For time and frequency domain correlated analysis.
Waveforms: FFT, max hold, min hold, average
Blackman-Harris – Max 11 peaks, threshold and excursion control

The Keysight MSOX3052G oscilloscope offers 500 MHz bandwidth, 5 GSa/s sampling rate, and up to 4 Mpts memory. With powerful analysis tools, a user-friendly interface, and fast waveform update rates, it is ideal for electronics, telecommunications, and automation applications. The MSOX3052G meets the needs of both students and professionals with signal decoding capabilities and various connectivity options.

Measurement Functions of the Keysight MSOX3052G Oscilloscope

The Keysight MSOX3052G oscilloscope delivers precise measurement capabilities with a waveform update rate of up to 1 million waveforms per second. This allows users to easily observe and analyze complex and rapidly changing electronic signals. With a 500 MHz bandwidth and two measurement channels, this device is suitable for a variety of applications in research and development, as well as in educational and industrial environments.

DSOX3012G Keysight Oscilloscope
MSOX3052G Keysight Oscilloscope

User-Friendly and Intuitive Design:

Equipped with a large color touchscreen, the Keysight MSOX3052G simplifies operation and waveform monitoring. Features like Auto Scale and Zone Trigger further minimize setup time and optimize measurement processes. The intuitive interface, with recognizable icons, allows users to quickly learn and efficiently use the device.

Powerful Analysis Tools:

The MSOX3052G oscilloscope offers a variety of powerful analysis tools, including automatic measurements, FFT analysis, and digital signal decoding capabilities. With the ability to save and analyze data directly on the device, you can easily check and assess signal quality, identify faults, and optimize circuit designs. The capability to export data and waveform images also makes it convenient for reporting and sharing measurement results.

Equipped with WaveGen Functionality on the Oscilloscope:

The Keysight MSOX3052G oscilloscope is equipped with the WaveGen functionality. This feature provides the ability to generate and customize a wide range of waveforms, meeting the testing and analysis needs across various fields. WaveGen allows users to create and modify waveforms, from basic types like sine, square, and triangle to more complex forms. This capability aids in simulating real-world signals and analyzing system responses to different signal types.

The WaveGen feature is directly integrated into the interface of the MSOX3052G oscilloscope, making waveform creation and usage simple and convenient. Users can quickly access and adjust parameters right on the touchscreen, streamlining the process of generating and working with waveforms.

Attribute

Brand

Review MSOX3052G Keysight Oscilloscope

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review MSOX3052G Keysight Oscilloscope
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    RECENT PRODUCT

    hotline techmaster
    Hotline: 0936 532 379
    zalo techmaster Zalo: 0936 532 379 messenger techmaster Nhắn tin Facebook
    support techmaster