facebook

Fluke Ti32 Infrared Camera

 

Features

Superior image quality

  • Delivers the clear, crisp images needed to find problems fast with its 320 x 240 sensor.
  • Identify even the smallest temperature differences that could indicate problems with thermal sensitivity (NETD)
  • Automatic alignment (parallax correction) of visual and infrared images with Fluke patented IR-Fusion®
  • Optional telephoto and wide angle lenses available for added versatility and special applications. (easily installable in the field)

INTRODUCTION FLUKE TI32 INFRARED CAMERA

When You Need to See the Smallest Visual and Thermal Details from Short or Long Distances

The Fluke Ti32 Infrared Camera combines powerful 320 x 240 resolution with IR-Fusion® Technology, the blending of digital and infrared images into a single image, delivering strikingly crisp detailed images, making problem detection extremely easy.  Identifying issues and easily reporting findings can be a challenge. AutoBlend™ lets you make a difference with each thermal inspection every time, as it gives you the ability to identify issues and report easier with partially transparent images.

Camera nhiệt Fluke Ti32

Fluke Ti32 Infrared Camera

Powerful and Versatile for Advanced Infrared Troubleshooting

If you are performing electrical and mechanical applications, including switch gear and utility inspections, the Ti32 is ideal for you. That’s because it has thermal sensitivity of ≤ 0.045 °C at 30 °C (45 mK) and a temperature range from -20 ° to 600 °C (-4 ° to 1112 °F). Stop relying on pen and paper – let the voice annotation feature make documenting specific details easier than ever. For added versatility in your special applications, add our field-installable telephoto and wide angle lenses.

For applications that require a high temperature range and low thermal sensitivity (NETD), the Ti400 is an alternative choice. It features wireless connectivity for quick and easy sharing of images, LaserSharp® Auto Focus for consistently in-focus images – every, single, time and a ruggedized high resolution 640 x 480 capacitive touch screen for quick menu navigation.

Features Fluke Ti32 Infrared Camera

Superior image quality

  • Delivers the clear, crisp images needed to find problems fast with its 320 x 240 sensor.
  • Identify even the smallest temperature differences that could indicate problems with thermal sensitivity (NETD)
  • Automatic alignment (parallax correction) of visual and infrared images with Fluke patented IR-Fusion®
  • Optional telephoto and wide angle lenses available for added versatility and special applications. (easily installable in the field)

Easy to use

  • Field replaceable batteries give you maximum flexibility no matter where your work takes you.
  • Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
  • No need to carry pen and paper—record findings by speaking into the imager. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference.
  • One-handed focus capability, emissivity correction, reflected background temperature compensation, and transmission correction increase the accuracy of measurements in most situations.
  • Adjustable hand strap for left-or right-handed use.
  • Everything needed to get started is included.

Rugged

  • Optimized for field use in challenging work environments.
  • Engineered and tested to withstand a 2 m (6.5 ft) drop for the ultimate peace of mind – When was the last time you dropped a tool or piece of equipment?
  • Withstands dust and water—tested to an IP54 rating.
  • Manufactured in the U.S.A.

Specifications Fluke Ti32 Infrared Camera

Temperature
Temperature measurement range (not calibrated below -10 °C) -20 °C to +600 °C (-4 °F to +1112 °F)
Temperature measurement accuracy ±2 °C or 2% (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes
Imaging Performance
Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation
Detector type 320 X 240 Focal Plane Array, uncooled microbolometer
Thermal sensitivity (NETD) ≤ 0.045 degrees C and 45 mK
Total pixels 76,800
Infrared spectral band 7.5 μm to 14 μm (long wave)
Visual (visible light) camera Industrial performance 2.0 megapixel
Minimum focus distance 46 cm (approx. 18 in)
Standard infrared lens type Field of view 23 ° x 17 °
Spatial resolution (IFOV) 1.25 mRad
Minimum focus distance 15 cm (approx. 6 in)
Optional telephoto infrared lens type Field of view 11.5 ° x 8.7 °
Spatial resolution (IFOV) 0.63 mRad
Minimum focus distance 45 cm (approx. 18 in)
Optional wide-angle infrared lens type Field of view 46 ° x 34
Spatial resolution (IFOV) 2.50 mRad
Minimum focus distance 7.5 cm (approx. 3 in)
Focus mechanism Manual, one-handed Smart Focus capability
Image Presentation
Palettes Standard Ironbow, blue-red, high contrast, amber, amber inverted, hot metal, grayscale, grayscale inverted
Ultra Contrast™ Ironbow ultra, blue-red ultra, high contrast ultra, amber ultra, amber inverted ultra, hot metal ultra, grayscale ultra, grayscale inverted
Level and span Smooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.5 °C (4.5 °F)
Minimum span (in auto mode) 5 °C (9 °F)
IR-Fusion® Information
Automatically aligned (parallax corrected) visual and IR blending Yes
Picture-in-picture (PIP) Three levels of on-screen IR blending displayed in center of LCD
Full screen infrared Three levels of on-screen IR blending displayed in center of LCD
Color alarms (temperature alarms) High-temperature alarm (user-selectable)
Image Capture and Data Storage
Image capture, review, save mechanism The Ti32 allows user to adjust palette, blending, level, span, IR-Fusion® mode, emissivity, and reflected background temperature compensation, and transmission correction on a captured image before it is stored.
Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager
Storage medium One-handed image capture, review, and save capability
File formats SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader
Export file formats w/SmartView® software Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp and .jpeg) files
General Specifications
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10% to 95% non-condensing
Display 9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover
Controls and adjustments User selectable temperature scale ( °C/ °F)
Language selection
Time/Date set
Emissivity selection
Reflected background temperature compensation
Transmission correction
User selectable hot spot and cold spot, and center point on the image (other custom markers and shapes in SmartView® software)
High temperature alarm
User selectable backlight: “Full Bright” or “Auto”
Information display preference
Software SmartView® full analysis and reporting software included
Batteries Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level
Battery life Four+ hours continuous use per battery pack (assumes 50% brightness of LCD)
Battery charge time 2.5 hours to full charge
AC battery charging Two-bay AC battery charger (110 V AC to 220 V AC, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter.
AC operation AC operation with included power supply (110 V AC to 220 V AC, 50/60 Hz). AC mains adapters included.
Power saving Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity
Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
Electromagnetic compatibility Meets all applicable requirements in EN61326-1:2006
C Tick IEC/EN 61326-1
US FCC CFR 47, Part 15 Class B
Vibration 0.03 g²/Hz (3.8 grms), IEC 68-2-6
Shock 25 g, IEC 68-2-29
Drop 2 m (6.5 ft) with standard lens
Dimensions (H x W x L) 27.7 x 12.2 x 17.0 cm (10.9 x 4.8 x 6.7 in)
Weight (battery included) 1.05 kg (2.3 lb)
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty Two-years (standard)
Recommended calibration cycle Two-years (assumes normal operation and normal aging)
Supported languages Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
Brand

Review Fluke Ti32 Infrared Camera

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Fluke Ti32 Infrared Camera
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    RECENT PRODUCT

    hotline techmaster
    Hotline: 0936 532 379
    zalo techmaster Zalo: 0936 532 379 messenger techmaster Nhắn tin Facebook
    support techmaster