SPECIFICATIONS CHROMA 19036 WOUND COMPONENT EST ANALYZER
AC/DC Withstanding Test: AC: 0.05~5.0kV / DC : 0.05~6.0kV
Load Regulation: ≦(1% of output + 0.1% of full scale)
Voltage Accuracy: ± ( 1% of setting + 0.1% of full scale)
Voltage Resolution: 2V
Cutoff Current: AC: 0.001mA~120mA (Voltage ≦4kV); AC: 0.001mA~100mA (Voltage >4kV); DC: 0.0001mA~20mA
Current Accuracy: ± (1% of reading + 0.5% of range)
Test Timer: 0.3 ~ 999 sec., and continue; Ramp / Fall / Dwell time:0.1 ~ 999 sec., and off
Output Frequency: 50Hz / 60Hz (for AC)
Waveform: Sine wave (for AC)
– Insulation Resistance Test
Output Voltage: DC : 0.050 ~ 5.000kV, Steps : 0.002kV
Load Regulation: ≦(1% of output + 0.1% of full scale)
Voltage Accuracy: ± ( 1% of setting + 0.1% of full scale)
IR Range: 0.1MΩ ~ 50GΩ
Resistance Accuracy:
>1kV: 1MΩ ~ 1GΩ : ± (3% of reading + 0.1% of full range); 1GΩ ~ 10GΩ : ± (7% of reading + 2% of full range ); 10GΩ ~ 50GΩ : ± (10% of reading + 1% of full range)
≧0.5kV and ≦1kV: 0.1MΩ ~ 1GΩ : ± (3% of reading + 0.1% of full range); 1GΩ ~ 10GΩ : ± (7% of reading + 2% of full range ); 10GΩ ~ 50GΩ : ± (10% of reading + 1% of full range)
<0.5kV: 1MΩ ~ 1GΩ : ± (5% of reading + (0.2*500/Vs)% of full scale)
– Impulse Winding Test Chroma 19036
Applied Voltage, Step, and Energy: 0.5 ~ 6kV ,10V Step ,Max 0.21 Joules
Inductance Test Range: More than 10uH
Sampling Speed: 10bit / 5ns (200MHz)
Sampling Range: 11 Ranges
Pulse Number: 1~32, Dummy Pulse Number: 0~9
Detection Mode: Area / Differential Area;Flutter/ Laplacian Detection
– DC Resistance Measurement
Test Signal: <DC 10V , <DC 200mA
Measurement Range: 0.1mΩ~ 500kΩ
– Measurement Accuracy:
100mΩ: ± (0.5% of reading + 1% of full range)
1Ω: ± (0.5% of reading + 0.2% of full range)
10Ω: ± (0.5% of reading + 0.05% of full range)
100Ω: ± (0.5% of reading + 0.05 % of full range)
1kΩ: ± (0.5% of reading + 0.05 % of full range)
10kΩ: ± (0.5% of reading + 0.05 % of full range)
100kΩ: ± (0.5% of reading + 0.05 % of full range)
– Flashover Detection Chroma 19036
Detection Current: Programmable setting AC : 20mA ; DC : 10mA
– Contact Check Function
Contact Check: OSC (open/short check); HFCC (High Frequency Contact Check); HSCC (High Speed Contact Check; winding DCR check)
– Electrical Hazard Protection Function
Ground Fault Interrupt: 0.5mA ±0.25mA AC, ON/OFF
Key Lock: Yes (password control)
Interlock: YES
Indication, Alarm: GO: Short sound, Green LED; NG: Long sound, Red LED
Memory Storage: 200 sets, max. 40 steps per set
– Interface: Standard: RS232, Handler, USB, LAN interface
– General
Operation Environment: Temperature: 0°C ~ 45°C, Humidity: 15% to 95% R.H@≦ 40°C
Power Consumption: No Load: <150VA ; Rated Load: <1000VA
Power Requirements: 90 ~ 264Vac, 47 ~ 63Hz
Dimension (W ×H ×D): 428 × 177 × 500mm / 16.850 x 6.969 x 19.685 inch
Weight: 26kg / 57.32 lbs
Introduction Chroma 19036 Wound Component EST Analyzer
The industry’s first Wound Component Electrical Safety Test (EST) Analyzer that combines impulse winding, AC/DC hipot, insulation resistance and DC resistance test measurement functions. Chroma 19036 Wound Component EST Analyzer has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement with a maximum output of up to 40 channels. Capable of outputting and measuring AC 100mA/DC 20mA, Chroma’s 19036 is suitable for testing to high power motor standards like UL 1004-1. Its 500VA design is also compliant with the output power requirements of EC/UL standards. Wound component applications include EV motors, servomotors, ascension motors, transformers and solenoid valves.
Features Chroma 19036
– 5 in 1 (10 channels) composite analyzer (ACWV / DCWV/ IR / Impulse / DCR)
– Hi-pot test: 5kVac / 6kVdc; HSCC( High Speed Contact Check); 500 VA output
– Insulation Resistance test: 5kV Max.
– Impulse Winding Test (IWT): 6kV impulse voltage; High sampling rate (200MHz)
– DCR measurement: 4-wire DCR measurement; △ / Y motor winding calculation
– Support max. 40 channels scanning test
– English, Traditional Chinese and Simplified Chinese User Interface
– USB waveform storage& Hard copy function
– Graphic color display
– Standard LAN, USB, RS232 interface
– GFI (Ground Fault Interrupt) for body protection
– 2-Year factory warranty
Review CHROMA 19036 WOUND COMPONENT EST ANALYZER