SPECIFICATIONS APC EASY UPS SRV2KIL
+ Overview
Presentation:
High quality, Double-conversion On-line UPS designed for essential power protection needs even in the most unstable power conditions.
Lead time: Usually in Stock
+ Main
Main Input Voltage: 230 V
Other Input Voltage:
220 V
240 V
Main Output Voltage: 230 V
Other Output Voltage:
220 V
240 V
Rated power in W: 1600 W
Rated power in VA: 2000 VA
Input Connection Type: IEC 60320 C14
Output connection type: 4 IEC 60320 C13
Cable length: 1.52 m
Number of cables: 1
Provided equipment:
1 IEC 60320 C13 to Schuko power cable
1 IEC 60320 C13 to C14 power cable
1 USB cable
1 RS-232 configuration cable
1 external battery pack
1 battery cable
user manual
+ Batteries & Runtime
Battery type: Lead-acid battery
Battery voltage: 72 V
Number of battery filled slots: 0
Number of battery free slots: 0
Battery recharge time: 5.5 h
Battery life: 3…5 year(s)
Battery charger power: 350 W rated
Battery option:
SRV72BP-9A 1 1944 VAh
SRV72BP-9A 2 2916 VAh
SRV72BP-9A 3 3888 VAh
SRV72BP-9A 4 4860 VAh
+ General
Number of power module filled slots: 0
Number of power module free slots: 0
Redundant: No
+ Physical
Colour: Black (RAL 7010)
Height: 33.6 cm
Width: 33.5 cm
Depth: 42.5 cm
Net weight: 45.4 kg
Mounting location: Front
Mounting preference: No preference
Mounting mode: Not rack-mountable
USB compatible: Yes
Mounting position: Vertical
+ Input
Input voltage limits:
110…285 V half load
160…280 V full load
Network frequency: 40…70 Hz auto sensing
+ Output
Maximum configurable power in VA: 2000 VA
Maximum configurable power in W: 1600 W
Output frequency: 50/60 Hz +/- 3 Hz sync to mains
Harmonic distortion: 3 %
UPS type: Double conversion online
Wave type: Sine wave
Efficiency: 88 % (full load)
Additional information: Configurable for 220 : 230 or 240 nominal output voltage
Bypass type: Internal bypass (automatic and manual)
Crest factor: 3 : 1.
+ Conformance
Product certifications:
CE
UKCA
EAC
TISI
Standards:
EN/IEC 62040-1:2019/A11:2021
EN/IEC 62040-2:2006/AC:2006
EN/IEC 62040-2:2018
+ Environmental
Ambient air temperature for operation: 0…40 °C
Relative humidity: 0…95 % non-condensing
Operating altitude: 0…3000 m
Ambient air temperature for storage: -20…50 °C
Storage Relative Humidity: 0…95 % non-condensing
Storage altitude: 0…15000 m
Acoustic level: 50 dBA
Heat dissipation: 745 Btu/h
IP degree of protection: IP20
+ Communications & Management
Alarm: Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Free slots: 1
Control panel: Multifunction LCD status and control console
+ Surge Protection and Filtering
Surge energy rate: 600 J
+ Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 2
Package 1 Height: 46.5 cm
Package 1 Width: 56 cm
Package 1 Length: 56.5 cm
Package 1 Weight: 49.3 kg
+ Offer Sustainability
REACh Regulation: REACh Declaration
EU RoHS Directive:
Compliant
EU RoHS Declaration
Mercury free: Yes
China RoHS Regulation:
China RoHS declaration
Pro-active China RoHS declaration (out of China RoHS legal scope)
RoHS exemption information: Yes
Introduction APC EASY UPS SRV2KIL
Features APC Easy UPS SRV2KIL
High Efficiency of APC Easy UPS SRV2KIL
• Up to 94% efficiency in on-line mode and 91% in battery mode – 6000/10,000 VA
• Up to 88% – 90% efficiency in on-line mode and 93% – 94% in ECO mode – 1000/2000/3000 VA
ECO Mode/Green Mode
• An energy saving mode where the input voltage regulation range can be set/modified through the LCD
High Power Factor of APC Easy UPS SRV2KIL
• More real output power in watts: 0.8 PF for 1000/2000/ 3000 VA, and unity PF for 5000 to 20,000 VA
True Double-conversion
• Provides tight voltage, frequency regulation, and zero transfer time for reactive loads (machinery, lab equipment, etc.)
Emergency Power Off (EPO)
• Immediately remove power to all connected equipment in the event of emergency (applicable to standard and extended runtime 6000/10,000 VA models)
Wide Input Voltage Range of APC Easy UPS SRV2KIL
• 60% Load: 110 – 300 Vac
• Allow for unstable power environment
Simplified Monitoring and Management
• USB and serial ports for UPS management with PowerChute™ Serial Shutdown software*
• Optional Network Management Card supports networkbased monitoring
Intelligent Battery Management
• Maximises battery performance, life, and reliability through intelligent precision temperature compensated charging
Over Voltage Cut-off Device (OVCD)
• Under special application with high voltage condition, OVCD protection will prevent the damage of UPS components and extend the lifespan of the UPS
LCD/LED Display
• Intuitive interface provides detailed and accurate information about UPS status with ability to configure locally
Safety Agency Approved
• Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment
Built-in Automatic Bypass
• Supplies utility power to the connected loads in the event of a UPS power overload or fault
Review APC EASY UPS SRV2KIL (On-Line, 2000VA/1600W, Tower, 230V, 4x IEC C13 outlets, Intelligent Card Slot, LCD, Extended runtime)
There are no reviews yet.