SPECIFICATIONS KYORITSU 4200 EARTH CLAMP TESTERS
Earth resistance Auto range
20.00/200.0/1500Ω
±1.5%±0.05Ω(0.00 – 20.99Ω)*
±2%±0.5Ω(16.0 – 99.9Ω)
±3%±2Ω(100.0 – 209.9Ω)
±5%±5Ω(160 – 399Ω)
±10%±10Ω(400 – 599Ω)
AC current (50Hz/60Hz) Auto range
Values are displayed, but accuracy isn’t guaranted(600 – 1580Ω)
100.0/1000mA/10.00/30.0A
±2%±0.7mA(0.0 – 104.9mA)
±2%(80mA – 31.5A)
Operating indication
Earth resistance function :
Constant voltage injection
Current detection (Frequency : Approx.2400Hz)
Dual Integration
AC current function : Successive approximation
Over-range indication
“OL”is displayed when input exceeds the upper limit of a measuring range
Response time
Approx. 7 seconds (Earth resistance)
Approx. 2 seconds (AC current)
Sample rate
Approx. 1 times per second
Current consumption
Approx. 50mA (max.100mA)
Measurement time
Approx.12 hours (when R6 is used)
Approx.24 hours (when LR6 is used)
Auto power-off
Turns power off about 10 minutes after the last button operation.
Conductor size
Approx. Ø32mm
Applicable standards
IEC 61010-1 CAT Ⅳ 300V Pollution degree2
IEC 61010-2-032, IEC 61326 (EMC)
Power source
DC6V : R6(sizeAA manganese battery) x 4
or LR6 (sizeAA alkaline battery) x 4
Dimensions
246(L)×120(W)×54(D)mm
Weight
Approx. 780g (including batteries)
Included Accessories
R6 x 4, Instruction manual
8304 (Resister for operation check)
9166 (Carrying case[Hard])
Introduction Kyoritsu 4200
This instrument is a digital clamp-on earth resistance tester, and it is used in multi- earthed systems. Can measure the earth resistance by simply clamping around the earthed wires. This instrument also equips AC current function to measure current up to 30A same as our traditional leakage clamp meters. A single earthing cannot be measured. (only for multiple-earthing system)
Features Kyoritsu 4200
• The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes.
(The Multiple Earthing System.)
• True RMS
Accurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A
• Noise Check Function
A function to detect current, which effects on an earth resistance measurement and display “NOISE” mark on the LCD.
• Memory function
Save and display up to 100 measurement data.
• Data hold function / Buzzer function / Back light function
• Compliant with Safety Standards of IEC 61010-1 : CAT IV 300V Pollution degree2
Review KYORITSU 4200 EARTH CLAMP TESTERS
There are no reviews yet.