Specifications 1-Year | |||
Fluke-721Ex-1601 | Low pressure sensor | ||
Range | Resolution | Accuracy | |
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +100 psi, -0.83 bar to 6.9 bar |
0.01 psi, 0.0001 bar |
0.025% of full scale | |
Fluke-721Ex-1603 | Low pressure sensor | ||
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +300 psi, -0.83 bar to 20 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-1605 | Low pressure sensor | ||
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +500 psi, -0.83 bar to 34.5 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-1610 | Low pressure sensor | ||
0 psi to +1000 psi, 0.00 bar to 69 bar |
0.1 psi, 0.001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +500 psi, -0.83 bar to 34.5 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-1615 | Low pressure sensor | ||
Range | Resolution | Accuracy | |
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +1500 psi, 0.00 bar to 103.4 bar |
0.1 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-1630 | Low pressure sensor | ||
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +3000 psi, 0.00 bar to 200 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
Fluke-721Ex-1650 | Low pressure sensor | ||
-14 psi to +16 psi, -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +5000 psi, 0.00 bar to 345 bar |
0.1 psi, 0.01 bar |
0.035% of full scale | |
Fluke-721Ex-3601 | Low pressure sensor | ||
Range | Resolution | Accuracy | |
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 to +100 psi, -0.83 bar to 6.9 bar |
.01 psi, 0.0001 bar |
0.025% of full scale | |
Fluke-721Ex-3603 | Low pressure sensor | ||
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +300 psi, -0.83 bar to 20 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-3605 | Low pressure sensor | ||
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
-12 psi to +500 psi, -0.83 bar to 34.5 bar |
0.01 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-3610 | Low pressure sensor | ||
Range | Resolution | Accuracy | |
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +1000 psi, 0.00 bar to 69 bar |
0.1 psi, 0.001 bar |
0.025% of full scale | |
Fluke-721Ex-3615 | Low pressure sensor | ||
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +1500 psi, 0.00 bar to 103.4 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
Fluke-721Ex-3630 | Low pressure sensor | ||
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +3000 psi, 0.00 bar to 200 bar |
0.1 psi, 0.01 bar |
0.025% of full scale | |
Fluke-721Ex-3650 | Low pressure sensor | ||
-14 psi to +36 psi, -0.97 bar to 2.48 bar |
0.001 psi, 0.0001 bar |
0.025% of full scale | |
High pressure sensor | |||
0 psi to +5000 psi, 0.00 bar to 345 bar |
0.1 psi, 0.01 bar |
0.035% of full scale | |
General Specifications | |||
Instrument setup recall | Last used on power-up | ||
Environmental | Operating temperature -10°C to +45°C Storage temperature (without batteries) -20°C to +60°C |
||
Altitude | 2,000 m | ||
Ingress protection | IP-40 | ||
Power requirements | 6.0 V DC | ||
Battery life | >35 hours, typical usage | ||
Batteries required | (4) Standard AA cells | ||
Dimensions (H x W x D) | 7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm) | ||
Weight | 03539 kg (1 lb 3 oz) | ||
Connectors/ports pressure | Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe | ||
Electrical and Temperature Measurement 1-Year | |||
Function | Range | Resolution | Accuracy |
mA measure | 0 to 24 mA | 0.001 mA | ±0.015% of rdg ±0.002mA |
Temperature Effect | |||
No effect on accuracy on all functions from 15°C to 35°C | |||
Add ±0.002% F.S./°C for temps outside of 15°C to 35°C |