facebook

Fluke 572-2 High Temperature Infrared Thermometer

 

Features

  • High temperature infrared thermometer that measures from -30°C to 900°C (-22°F to 1652°F)
  • Offers an ultra-high 60:1 distance-to-spot ratio with dual laser sighting for fast, accurate targeting
  • Features a user-selectable multi-language interface
  • Displays the temperature plus MAX, MIN, DIF, AVG temperature
  • Provides adjustable emissivity and a predefined emissivity table

Introduction Fluke 572-2 High Temperature Infrared Thermometer

Fluke 572-2 High Temperature Infrared Thermometer measures temperatures up to 900°C

The Fluke 572-2 High-Temperature Infrared Thermometer is the ideal tool for high-temperature industrial environments all around the world. Whether you work in power utility, metal refining and smelting, glass, cement or petrochemical environments, the Fluke 572-2 offers the rugged performance accuracy you need to get the job done, backed by the most trusted name in test tools. The simple, three-button on-screen menu interface saves time and makes even complex measurements easy. With just a few pushes of a button you can adjust emissivity, start data logging, or turn on and off alarms. The 60:1 distance-to-spot ratio with dual laser sighting helps pinpoint the target fast, making it easier to measure small objects from a long distance.

Features

  • High temperature infrared thermometer that measures from -30°C to 900°C (-22°F to 1652°F)
  • Offers an ultra-high 60:1 distance-to-spot ratio with dual laser sighting for fast, accurate targeting
  • Features a user-selectable multi-language interface
  • Displays the temperature plus MAX, MIN, DIF, AVG temperature
  • Provides adjustable emissivity and a predefined emissivity table

Specifications

Infrared Measurements
Infrared temperature range -30°C to 900°C (-22°F to 1652°F)
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C) ≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater
≥ -10°C to < 0°C: ±2°C
< -10°C: ±3°C
≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater
≥ 14°F to < 32°F: ±4°F
< 14°F: ±6°F
IR repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Distance: Spot 60:1 (calculated at 90% energy)
Minimum spot size 19 mm
Laser sighting Offset dual laser, output < 1 mW
Spectral response 8 μm to 14 μm
Response time (95%) < 500 ms
Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Contact Measurements
K-type thermocouple input temperature range -270°C to 1372°C (-454°F to 2501°F)
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C) < -40°C: ±(1°C + 0.2° / 1°C)
≥ -40°C: ±1% or 1°C, whichever is greater
< -40°F: ±(2°F + 0.2° / 1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
K-type thermocouple 0.1°C / 0.1°F
K-type thermocouple repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Measurement Options
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Switchable celsius and fahrenheit Yes
Backlight Two levels, normal and extra bright for darker environments
Probe input K-type thermocouple simultaneous display of probe and IR temperature
Trigger lock Yes
Data storage 99 points
Display Dot matrix 98 x 96 pixels with function menus
Communication USB 2.0
K-Type Thermocouple Specifications
Measurement range (bead probe) -40°C to 260°C (-40°F to 500°F)
Accuracy ±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
Cable length 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
General Specifications
Safety and compliance IEC 60825-1
FDA Laser Class II
IEC 61326-1
CE Complaint
CMC # 01120009
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-4°F to 140°F)
Relative humidity 10% to 90% RH non-condensing up to 30°C (86°F)
Operating altitude 2000 meters above mean sea level
Weight 0.322 kg (0.7099 lb)
Power 2 AA batteries
Battery life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)
Brand

Review Fluke 572-2 High Temperature Infrared Thermometer

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Fluke 572-2 High Temperature Infrared Thermometer
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    RECENT PRODUCT

    hotline techmaster
    Hotline: 0936 532 379
    zalo techmaster Zalo: 0936 532 379 messenger techmaster Nhắn tin Facebook
    support techmaster