SPECIFICATIONS FLUKE 319 CLAMP METERS
General specifications
Digital display: 6000 count resolution
Low battery Indication: Displays a signal when the batteries are below their required voltage
Power source: Three AAA IEC LR03 batteries
Clamp opening size: 1.45 in (37 mm)
Jaw diameter: 1.45 in (37 mm)
Dimensions (L x W x H): 6.39 x 2.29 x 1.20 in (162.4 x 58.25 x 30.5 mm)
Weight: Approximately 13.5 oz (384 g) (batteries included)
Auto range: Available in Ohms
Safety:
CE
EN/IEC 61010-1 and IEC 61010-2-032
Measurement Category: 600V CAT III
319 Electrical specifications
+ Current AC
Range: 40.00 A, 600.0 A, 1000 A
Resolution: 0.01 A, 0.1 A, 1 A
Accuracy:
1.6% ±6 digit (50-60 Hz) {40 A}
2.5% ±8 digit (60-500 Hz) {40 A}
1.5% ±5 digit (50-60 Hz) {600/1000 A}
2.5% ±5 digit (60-500 Hz) {600/1000 A}
Crest Factor add 2% into spec for CF > 2: 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
AC response: rms
+ Current DC:
Range: 40.00 A, 600.0 A, 1000 A
Resolution: 0.01 A, 0.1 A, 1 A
Accuracy:
1.6% ±6 digit (40 A)
1.5% ±5 digit (600/1000 A)
+ Voltage AC:
Range 600.0 V
Resolution: 0.1 V
Accuracy: 1.5% ±5 digit (20-500Hz)
AC response: rms
+ Voltage DC:
Range: 600.0 V
Resolution: 0.1 V
Accuracy: 1% ±4 digit
+ Resistance:
Range:
400.0 Ω
4000 Ω
Resolution:
0.1 Ω
1 Ω
Accuracy: 1% ±5 digit
+ Continuity: ≤ 30 Ω
+ Inrush
Integration time: 100 ms
+ Frequency:
Range: 5.0 – 500.0 Hz
Accuracy: 0.5% ±5 digit
Trigger Level: 10 – 100 Hz ≥ 5 A, 5 – 10 Hz, 100 – 500 Hz ≥ 10 A
The accuracy specifications aply at 73 °F ±41 °F (23 °C ±5 °C)
Below 64 °F and above 82 °F (18 °C and above 28 °C) accuracy degrades at (0.1) times specification per °C.
True rms for ac V and ac A accuracy is specified from 5% to 100% of range.
Environmental specifications
Operating temperature: 14°F to 122°F (-10 °C to 50 °C)
Storage temperature: -40 °F to 140 °F (-40 °C to 60 °C)
Operating humidity:
Non-condensing (< 50 °F) (< 10 °C)
90% RH (50 °F to 86 °F) (10 °C to 30 °C)
75% RH (86 °F to 104 °F) (30 °C to 40 °C)
45% RH (104 °F to 122 °F) (40 °C to 50 °C)
(Without condensation)
Operating altitude: 1 mile (2000 meters) above mean sea level
Storage altitude: 7 miles (12,000 meters) above mean sea level
IP Rating: IP40
Vibration requirements: Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis
Drop test requirements: 3 ft (1 m) drop test, six sides, oak floor
EMI, RFI, EMC: Instrument unspecified for use in EMC field ≥ 0.1 V/m
Temperature coefficients:
0.1x (specified accuracy)/ °C
(<64 °F or > 82° F)
(<18 °C or > 28 °C)
Introduction Fluke 319 Clamp Meters
The Fluke 319 is designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments. It also offer AC/DC current measurements and has a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, the Fluke 319 also equip with In-rush current and Frequency functions for testing motors, lighting, etc.
Key Features
– Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement
– The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
– The large backlight display facilitates readings in dark environments
– Starting current (inrush) functionality (319) allows measurement of the starting current of electrical and lighting equipment, for example.
– Current frequency measurement
– Precision down to 0.01A and 0.1V
– 1000A/600A AC/DC current measurement
– 600V AC/DC voltage measurement
– 4000Ω resistance measurement
– Continuity beeper
– Auto off function enhances battery life, meaning the instrument can work when you need it screen store ‘hold’ function for capturing a measurement result on the screen
Review FLUKE 319 CLAMP METERS
There are no reviews yet.