facebook

Flelxible Isolation Ward

 

The Flexible Isolation Ward not only achieves continuous dynamic negative pressure control, isolates the infected patients, but also allows various treatments and monitoring devices working internally.

The Flexible Isolation Ward not only achieves continuous dynamic negative pressure control, isolates the infected patients, but also allows various treatments and monitoring devices working internally. The whole portable structure can be quickly assembled on site. Simplified design meets the requirements of low cost, rapid assembly and large-scale use in short time.

Features

  • Safety: One ward for one patient, avoid cross infection and environmental pollution, reduce the risk of medical staff;
  • Versatility: Negative pressure and positive pressure can be switched;
  • Convenience: Rapid assembly, rapid use, suitable for sudden public health events;
  • Reliability: It is made of polyurethane material and welded with high frequency, sealing without leakage; The ventilation system controlled by SEIMENS PLC and adopted double-layer HEPA filters, which can continuously maintain the negative pressure in the room. The blowers speed is adjusted according to the real-time pressure.
  • Economy: simple structure, economical investment.

Dimensions

  • Isolation ward (L *W*H): 2260mm*1720mm*1980mm
  • Buffer room (L *W*H):  1000mm*900mm*1980mm
  • Pass Box (L *W*H): 420mm*420mm*430mm

Negative pressure working mode:

  • Pressure range:  -5Pa~ -15Pa
  • Air change rate: 10~15time/hour
  • Microorganism on surface: ≤5cfu/cm2
  • Microorganism in air: ≤10cfu/m3
  • Noise: ≤50dB(A)

Positive pressure working mode:

  • Pressure range:  10Pa~ -20Pa
  • Air change rate: 10~15time/hour
  • Microorganism on surface: ≤5 cfu/cm2
  • Microorganism in air: ≤3 cfu/m3
  • Noise: ≤50dB(A)

Disinfection:

  • Built-in UV light OR connected to VHPS generator for whole room disinfection. SIP disinfect the HEPA filters.

Filtration efficiency:

  • Inlet HEPA filters:   H14, above 99.995%;
  • Exhaust HEPA filters: H14 double -layer, above 99.99995%

Assembly time: 45 min.

Power supply: 220V, 3 pcs sockets

Integrated Emergency Call Button

Brand

Review Flelxible Isolation Ward

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Flelxible Isolation Ward
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    RECENT PRODUCT

    hotline techmaster
    Hotline: 0908 173 345
    zalo techmaster Zalo: 0936 532 379 messenger techmaster Nhắn tin Facebook email techmaster Gửi Mail
    support techmaster