Pressure & Vacuum Calibration
Techmaster provides ISO/IEC 17025:2017 accredited Pressure calibration — accredited by ANAB (USA), traceable to the SI and recognized worldwide through ILAC-MRA. On-site service nationwide.
✓ Our calibration commitments
- ISO/IEC 17025 certificates with legal standing & global recognition
- Measurement traceability to the SI International System of Units
- On-site calibration at your facility, minimizing production downtime
- Look up & download E-Certificates online 24/7
What is Pressure calibration?
Pressure calibration determines the error of gauge, absolute, differential and vacuum instruments — pressure gauges, transmitters, digital pressure indicators. Techmaster’s ISO/IEC 17025:2017 lab is traceable to the SI pascal (Pa).
Pressure is critical in oil & gas, chemicals, food, pharma and boilers — where measurement error can cause safety hazards or process drift. Periodic calibration ensures operational safety and standards compliance.
Techmaster calibrates pressure with deadweight testers (pressure balances) and digital pressure standards, traceable to the pascal; aligned with DKD-R 6-1 and international guidance for pressure-gauge calibration.
Quantities & parameters we calibrate
Instruments Techmaster calibrates
Typical measurement ranges & CMC
The table below lists typical parameters & measurement ranges for this discipline.
| Parameter / Instrument | Typical measurement range | CMC / Measurement uncertainty |
|---|---|---|
| Gauge | 0 – 700 bar (up to 1000 bar) | [Verify against scope] |
| Vacuum | −1 – 0 bar | [Verify against scope] |
| Low pressure | 0 – 100 mbar | [Verify against scope] |
| Differential | 0 – 10 bar | [Verify against scope] |
| Safety valve | per working range | [Verify against scope] |
⚠ Note: The ranges & CMC below are typical reference values. Please verify against Techmaster’s official Scope of Accreditation before publishing — actual CMC depends on the reference standard, method and measurement conditions.
Reference standards & traceability
Pressure is traceable to the SI pascal (Pa) through certified pressure balances (deadweight testers) and digital pressure standards; referencing the DKD-R 6-1 / EURAMET cg-17 guides.
A trusted calibration partner for factories & labs
Internationally recognized
Our lab is ISO/IEC 17025:2017 accredited by ANAB (USA); certificates are recognized worldwide through ILAC-MRA.
SI traceability
Reference standards are traceable to the SI International System of Units, ensuring reliable, comparable measurement results.
On-site calibration
A mobile calibration capability performs work right at your facility, cutting downtime and equipment transport risk.
E-Certificate 24/7
Look up and manage certificates, history and recalibration reminders online anytime via portal.techmaster.us.
Two labs, nationwide reach
An HCMC head office and a Bac Ninh branch serve the southern and northern manufacturing regions quickly.
Trusted since 2014
Over 10 years serving electronics, EMS, semiconductor plants and labs across Vietnam with an experienced engineering team.
The Pressure calibration process at Techmaster
A transparent 6-step process to ISO/IEC 17025 — from request intake to certificate delivery and recalibration reminders.
Request & quotation
We log your equipment list, discipline and technical requirements, advise the scope and send a fast calibration quote.
Pickup or on-site
Our team collects the equipment from your site, or a mobile calibration unit performs the work right at your facility.
Perform calibration
Calibration is carried out using ISO/IEC 17025 methods, SI-traceable standards and controlled measurement conditions.
Certificate & label
We issue the calibration certificate (with error and measurement uncertainty) and apply a calibration label to the device.
Look up E-Certificate
Look up and download certificates online 24/7 via portal.techmaster.us and manage your full calibration history.
Recalibration reminder
Our system reminds you of the next recalibration at a suitable interval, keeping your compliance continuously valid.
Other calibration disciplines
Techmaster calibrates across 12 metrology disciplines. Explore related disciplines:
Frequently asked questions
What pressure ranges can Techmaster handle? +
Do you calibrate 4–20 mA pressure transmitters? +
Should safety valves have set-pressure testing? +
Is on-site pressure calibration accurate? +
Techmaster Electronics JSC
Please contact Techmaster using the details below. Our team is always ready to assist and answer any questions you may have. Thank you for trusting our services.
Head Office (Ho Chi Minh City)
Address: 175 Vo Nguyen Giap, An Khanh Ward, Ho Chi Minh City
Hotline: +84 908 173 345
Email: marketing@techmaster.com.vn
Bac Ninh Branch
Address: D1, Phu Dien Urban Area, Dong Nguyen Ward, Bac Ninh Province
Business Registration No.: 0312668882 (issued 28/02/2014)
Issued by: Department of Planning and Investment, Ho Chi Minh City
We are here and remain the right choice for you.
Techmaster’s technical staff are ready to address any questions, concerns or requests about our calibration information and services. Please complete the form below so we can respond to your enquiry.
Need ISO/IEC 17025 accredited calibration?
Get expert advice on the right calibration discipline and a fast quote from the Techmaster team.
