{"id":40573,"date":"2022-09-21T10:59:29","date_gmt":"2022-09-21T03:59:29","guid":{"rendered":"https:\/\/techmaster.com.vn\/?p=40573"},"modified":"2022-12-26T16:46:05","modified_gmt":"2022-12-26T09:46:05","slug":"temperature-and-humidity-meter-calibration","status":"publish","type":"post","link":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/","title":{"rendered":"Temperature And Humidity Meter Calibration"},"content":{"rendered":"<p><a href=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-47651\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg\" alt=\"Temperature And Humidity Meter Calibration\" width=\"2048\" height=\"1152\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #333333;\">Temperature And Humidity Meter is a device that measures the environment temperature &amp; humidity. This equipment is used in industrial production, medical facilities, cold storage, storage warehouses, buildings and even in households. Calibrate the Temperature And Humidity Meter to ensure it&#8217;s always efficient.<\/span><\/p>\n<p><span style=\"color: #333333;\">After assessing the temperature and humidity, we can actively adjust the product production process or control the environment, avoiding the risk of damaging <span class=\"trans\">end-product<\/span> and materials. We will introduce the Temperature And Humidity Meter Calibration Process<\/span><\/p>\n<div class=\"page\" title=\"Page 2\">\n<h2 class=\"layoutArea\"><span style=\"color: #333333;\"><strong>1. Scope of procedure<\/strong><\/span><\/h2>\n<div>\n<table style=\"width: 334px;\">\n<tbody>\n<tr>\n<td style=\"width: 99px; text-align: center;\"><span style=\"color: #333333;\"><strong>Unit Under Test Characteristics<\/strong><\/span><\/td>\n<td style=\"width: 103.734375px; text-align: center;\"><span style=\"color: #333333;\"><strong>Performance Range<\/strong><\/span><\/td>\n<td style=\"width: 150.265625px; text-align: center;\"><span style=\"color: #333333;\"><strong>Performance method<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 99px; text-align: left;\">\n<div class=\"page\" title=\"Page 2\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<div class=\"page\" title=\"Page 2\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #333333;\">Temperature<\/span><\/p>\n<div class=\"page\" title=\"Page 2\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #333333;\">Humidity<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/td>\n<td style=\"width: 103.734375px; text-align: left;\">\n<div class=\"page\" title=\"Page 2\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<div class=\"page\" title=\"Page 2\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #333333;\">(-30 \u00f7 140)\u00b0C<\/span><\/p>\n<div class=\"page\" title=\"Page 2\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #333333;\">(Up to) 95%RH<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/td>\n<td style=\"width: 150.265625px; text-align: left;\">\n<div class=\"page\" title=\"Page 2\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<div class=\"page\" title=\"Page 2\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #333333;\">Comparison to reference temperature &amp; humidity meter.<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span style=\"color: #333333;\"><strong>2. Standard and supporting device<\/strong><\/span><\/h2>\n<div class=\"page\" title=\"Page 2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #333333;\">&#8211; Temperature &amp; humidity generator: chamber ESPEC, KIMO, MEMMERT or equivalent<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Reference temperature &amp; humidity meter VAISALA or equivalent with accuracy better than 3 times UUT.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; DC Power Supply AGILENT, read out Multi-meter FLUKE (mA, V) or equivalent.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Small camera may need to be put inside of chamber if the meter didn\u2019t have logging function and the chamber don\u2019t have view through window.<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h2><span style=\"color: #333333;\"><strong>3.\u00a0Environment conditions<\/strong><\/span><\/h2>\n<div class=\"page\" title=\"Page 2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #333333;\">Temperature: (20 \u00f7 28)oC<\/span><br \/>\n<span style=\"color: #333333;\">Relative Humidity: (30 \u00f7 70)%RH<\/span><\/p>\n<h2><span style=\"color: #333333;\"><strong>4. Preparation<\/strong><\/span><\/h2>\n<div class=\"page\" title=\"Page 3\">\n<div class=\"layoutArea\">\n<div class=\"column\"><span style=\"color: #333333;\">&#8211; Visually inspect the Unit Under Test (UUT) for obvious damage that may affect accuracy and\/or operation and note any observations.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Connect UUT to suitable power and turn on.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; UUT that use graph paper, select and use correct type of paper supplied with UUT.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Turn on chamber, allow warm-up at least 10 minutes or follow manufacturer\u2019s instructions.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Technician must be familiar with calibration techniques and the operator manual of the UUT being calibrated, and the chamber being used.<\/span><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p style=\"text-align: center;\"><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/z-AweuIJkk0\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\" data-mce-fragment=\"1\"><\/iframe><\/p>\n<h2><span style=\"color: #333333;\"><strong>5.\u00a0Perform<\/strong><\/span><\/h2>\n<h3><span style=\"color: #333333;\"><strong>5.1 Temperature &amp; Humidity Meter<\/strong><\/span><\/h3>\n<div class=\"page\" title=\"Page 4\">\n<div class=\"layoutArea\">\n<div class=\"column\"><span style=\"color: #333333;\">&#8211; Perform at least 3 points low, mid, high of UUT range for each Temperature and Humidity function. Other test points may follow customer\u2019s requirements.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Put UUT\u2019s sensor, probe in the chamber or whole UUT into the chamber if it has internal sensor type.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Turn on reference meter, put the sensor inside the chamber through small hole located at sides of chamber. Close that hole by using accessories supply by maker.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; If there were no customer\u2019s requirement, perform calibration temperature function first.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Follow chamber manufacturer\u2019s manual, set up temperature test points.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; The humidity generate function may turn off in this process. Turn on camera and connect to the computer for visual record, in case needed.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Waiting for UUT and reference meter reading are stable. Record 5 consecutive measurement results.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Continue for remain temperature test points.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; For humidity test, the set point of temperature should be set up from 20oC up to 40oC, follow to the chamber manufacturer\u2019s manual. Then each humidity test point can be set up and easily to reach.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Waiting for UUT and reference meter reading are stable. Record and compare measured values.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Continue for remain humidity test points.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Calibration completed, set temperature of chamber back to room temperature.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Stop running mode of chamber, take out all UUT and reference sensor, and turn off chamber.<\/span><\/div>\n<h3><span style=\"color: #333333;\"><strong>5.2\u00a0Temperature &amp; Humidity Logger, Graph<\/strong><\/span><\/h3>\n<div class=\"page\" title=\"Page 5\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #333333;\">&#8211; Using same procedure at item 5.1.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; The UUT need to set up for logging before test. The interval of each logging is 1 minutes. Software and USB cable may be supplied from the customer.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; For Thermo-Hygrograph, specific recording paper need to be supplied from customer. This type of paper must be match exactly for each UUT model.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; After all test points are finished, stop running mode of chamber, take out all UUT and reference sensor, and turn off chamber.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Connect UUT to the computer, record measured value by software. Compare to reference meter readings at stable period measuring.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; For Thermo-Hygrograph, compare values of recording paper to reference measuring device.<\/span><\/p>\n<h3><span style=\"color: #333333;\"><strong>5.3 Temperature &amp; Humidity Transmitter<\/strong><\/span><\/h3>\n<div class=\"page\" title=\"Page 6\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #333333;\">&#8211; Using same procedure at item 5.1. If UUT didn\u2019t have indicator and power, a suitable DC power supply and Multi-meter (mA or V meter, depend on signal output of UUT).<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Connect UUT to suitable power, or use DC power supply, then turn on.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; Based on UUT\u2019 signal range and connection wiring, use multi-meter to measure and convert signal to temperature &amp; humidity:<\/span><\/p>\n<p style=\"padding-left: 40px;\"><span style=\"color: #333333;\">\u2022\u00a0Example, transmitter 0-10VDC with temperature range from 0~50oC, output signal measured value is 7.5VDC, that converted to 37.5oC for temperature.<\/span><br \/>\n<span style=\"color: #333333;\">\u2022 Example, transmitter 4-20mA with humidity range from 0~100%RH, output signal measured value is 16mA, that converted to 75%RH for humidity.<\/span><\/p>\n<p><span style=\"color: #333333;\">&#8211; Put the sensor of UUT inside the chamber and follow procedure at 5.1 for setting test points and record stable reading of UUT and reference meter.<\/span><\/p>\n<h2><span style=\"color: #333333;\"><strong>6. Tolerance<\/strong><\/span><\/h2>\n<div class=\"page\" title=\"Page 6\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><span style=\"color: #333333;\">&#8211; Tolerance given by the customer will be applied for all measurement, unless otherwise provisions.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; If the customer does not offer any rule, the specifications of manufacturer or other source of reference will be used.<\/span><br \/>\n<span style=\"color: #333333;\">&#8211; If not, the tolerance of the equipment will be \u00b1 1\u00b0C and 5%RH for whole measuring range.<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; Temperature And Humidity Meter is a device that measures the environment temperature &amp; humidity. This equipment is used in industrial production, medical facilities, cold storage, storage warehouses, buildings and even in households. Calibrate the Temperature And Humidity Meter to ensure it&#8217;s always efficient. After assessing the temperature and humidity, we can actively adjust the [&#8230;]\n","protected":false},"author":9,"featured_media":47651,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[62,456],"tags":[],"class_list":["post-40573","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bai-viet-moi","category-calibration-process"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.8 (Yoast SEO v26.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Temperature And Humidity Meter Calibration - Techmaster Electronics JSC<\/title>\n<meta name=\"description\" content=\"Temperature And Humidity Meter is used in industrial production, medical facilities, cold storage, storage warehouses, buildings and even\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Temperature And Humidity Meter Calibration\" \/>\n<meta property=\"og:description\" content=\"Temperature And Humidity Meter is used in industrial production, medical facilities, cold storage, storage warehouses, buildings and even\" \/>\n<meta property=\"og:url\" content=\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/\" \/>\n<meta property=\"og:site_name\" content=\"Techmaster Electronics JSC\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/techmaster.electronics.jsc\" \/>\n<meta property=\"article:published_time\" content=\"2022-09-21T03:59:29+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-12-26T09:46:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2048\" \/>\n\t<meta property=\"og:image:height\" content=\"1152\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Nguyen Thuy\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@techmastervn\" \/>\n<meta name=\"twitter:site\" content=\"@techmastervn\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Nguyen Thuy\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/\"},\"author\":{\"name\":\"Nguyen Thuy\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/f84389eda649db5897c20f2834330f93\"},\"headline\":\"Temperature And Humidity Meter Calibration\",\"datePublished\":\"2022-09-21T03:59:29+00:00\",\"dateModified\":\"2022-12-26T09:46:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/\"},\"wordCount\":819,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg\",\"articleSection\":[\"B\u00e0i vi\u1ebft m\u1edbi\",\"Calibration Process\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#respond\"]}],\"copyrightYear\":\"2022\",\"copyrightHolder\":{\"@id\":\"https:\/\/techmaster.com.vn\/#organization\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/\",\"url\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/\",\"name\":\"Temperature And Humidity Meter Calibration - Techmaster Electronics JSC\",\"isPartOf\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg\",\"datePublished\":\"2022-09-21T03:59:29+00:00\",\"dateModified\":\"2022-12-26T09:46:05+00:00\",\"description\":\"Temperature And Humidity Meter is used in industrial production, medical facilities, cold storage, storage warehouses, buildings and even\",\"breadcrumb\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#primaryimage\",\"url\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg\",\"contentUrl\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg\",\"width\":2048,\"height\":1152,\"caption\":\"Temperature And Humidity Meter Calibration\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Trang ch\u1ee7\",\"item\":\"https:\/\/techmaster.com.vn\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Temperature And Humidity Meter Calibration\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/#website\",\"url\":\"https:\/\/techmaster.com.vn\/en\/\",\"name\":\"Techmaster Electronics JSC\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/techmaster.com.vn\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Organization\",\"Place\"],\"@id\":\"https:\/\/techmaster.com.vn\/en\/#organization\",\"name\":\"Techmaster Electronics JSC\",\"url\":\"https:\/\/techmaster.com.vn\/en\/\",\"logo\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#local-main-organization-logo\"},\"image\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#local-main-organization-logo\"},\"sameAs\":[\"https:\/\/www.facebook.com\/techmaster.electronics.jsc\",\"https:\/\/x.com\/techmastervn\",\"https:\/\/www.instagram.com\/techmastervietnam\",\"https:\/\/myspace.com\/techmastervietnam\",\"https:\/\/www.youtube.com\/c\/TechmasterElectronicsJSC\",\"https:\/\/www.pinterest.com\/techmasterelectronicsjsc\/\",\"https:\/\/vi.wikipedia.org\/wiki\/Th\u00e0nh_vi\u00ean:Techmastervietnam\",\"https:\/\/twitter.com\/techmastervn\",\"https:\/\/www.linkedin.com\/company\/techmaster-vietnam\/\"],\"telephone\":[],\"contactPoint\":{\"@type\":\"ContactPoint\",\"email\":\"marketing@techmaster.com.vn\"},\"openingHoursSpecification\":[{\"@type\":\"OpeningHoursSpecification\",\"dayOfWeek\":[\"Monday\",\"Tuesday\",\"Wednesday\",\"Thursday\",\"Friday\",\"Saturday\",\"Sunday\"],\"opens\":\"09:00\",\"closes\":\"17:00\"}],\"email\":\"marketing@techmaster.com.vn\",\"areaServed\":\"Vietnam\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/f84389eda649db5897c20f2834330f93\",\"name\":\"Nguyen Thuy\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/21c554a342ff40286215b03bcd5a84e3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/21c554a342ff40286215b03bcd5a84e3?s=96&d=mm&r=g\",\"caption\":\"Nguyen Thuy\"},\"url\":\"https:\/\/techmaster.com.vn\/en\/author\/mimi2021\/\"},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#local-main-organization-logo\",\"url\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png\",\"contentUrl\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png\",\"width\":335,\"height\":62,\"caption\":\"Techmaster Electronics JSC\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Temperature And Humidity Meter Calibration - Techmaster Electronics JSC","description":"Temperature And Humidity Meter is used in industrial production, medical facilities, cold storage, storage warehouses, buildings and even","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/","og_locale":"en_US","og_type":"article","og_title":"Temperature And Humidity Meter Calibration","og_description":"Temperature And Humidity Meter is used in industrial production, medical facilities, cold storage, storage warehouses, buildings and even","og_url":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/","og_site_name":"Techmaster Electronics JSC","article_publisher":"https:\/\/www.facebook.com\/techmaster.electronics.jsc","article_published_time":"2022-09-21T03:59:29+00:00","article_modified_time":"2022-12-26T09:46:05+00:00","og_image":[{"width":2048,"height":1152,"url":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg","type":"image\/jpeg"}],"author":"Nguyen Thuy","twitter_card":"summary_large_image","twitter_creator":"@techmastervn","twitter_site":"@techmastervn","twitter_misc":{"Written by":"Nguyen Thuy","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#article","isPartOf":{"@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/"},"author":{"name":"Nguyen Thuy","@id":"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/f84389eda649db5897c20f2834330f93"},"headline":"Temperature And Humidity Meter Calibration","datePublished":"2022-09-21T03:59:29+00:00","dateModified":"2022-12-26T09:46:05+00:00","mainEntityOfPage":{"@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/"},"wordCount":819,"commentCount":0,"publisher":{"@id":"https:\/\/techmaster.com.vn\/en\/#organization"},"image":{"@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#primaryimage"},"thumbnailUrl":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg","articleSection":["B\u00e0i vi\u1ebft m\u1edbi","Calibration Process"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#respond"]}],"copyrightYear":"2022","copyrightHolder":{"@id":"https:\/\/techmaster.com.vn\/#organization"}},{"@type":"WebPage","@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/","url":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/","name":"Temperature And Humidity Meter Calibration - Techmaster Electronics JSC","isPartOf":{"@id":"https:\/\/techmaster.com.vn\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#primaryimage"},"image":{"@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#primaryimage"},"thumbnailUrl":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg","datePublished":"2022-09-21T03:59:29+00:00","dateModified":"2022-12-26T09:46:05+00:00","description":"Temperature And Humidity Meter is used in industrial production, medical facilities, cold storage, storage warehouses, buildings and even","breadcrumb":{"@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#primaryimage","url":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg","contentUrl":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/Temperature-And-Humidity-Meter-Calibration-1-scaled.jpg","width":2048,"height":1152,"caption":"Temperature And Humidity Meter Calibration"},{"@type":"BreadcrumbList","@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Trang ch\u1ee7","item":"https:\/\/techmaster.com.vn\/en\/"},{"@type":"ListItem","position":2,"name":"Temperature And Humidity Meter Calibration"}]},{"@type":"WebSite","@id":"https:\/\/techmaster.com.vn\/en\/#website","url":"https:\/\/techmaster.com.vn\/en\/","name":"Techmaster Electronics JSC","description":"","publisher":{"@id":"https:\/\/techmaster.com.vn\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/techmaster.com.vn\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Organization","Place"],"@id":"https:\/\/techmaster.com.vn\/en\/#organization","name":"Techmaster Electronics JSC","url":"https:\/\/techmaster.com.vn\/en\/","logo":{"@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#local-main-organization-logo"},"image":{"@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#local-main-organization-logo"},"sameAs":["https:\/\/www.facebook.com\/techmaster.electronics.jsc","https:\/\/x.com\/techmastervn","https:\/\/www.instagram.com\/techmastervietnam","https:\/\/myspace.com\/techmastervietnam","https:\/\/www.youtube.com\/c\/TechmasterElectronicsJSC","https:\/\/www.pinterest.com\/techmasterelectronicsjsc\/","https:\/\/vi.wikipedia.org\/wiki\/Th\u00e0nh_vi\u00ean:Techmastervietnam","https:\/\/twitter.com\/techmastervn","https:\/\/www.linkedin.com\/company\/techmaster-vietnam\/"],"telephone":[],"contactPoint":{"@type":"ContactPoint","email":"marketing@techmaster.com.vn"},"openingHoursSpecification":[{"@type":"OpeningHoursSpecification","dayOfWeek":["Monday","Tuesday","Wednesday","Thursday","Friday","Saturday","Sunday"],"opens":"09:00","closes":"17:00"}],"email":"marketing@techmaster.com.vn","areaServed":"Vietnam"},{"@type":"Person","@id":"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/f84389eda649db5897c20f2834330f93","name":"Nguyen Thuy","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/21c554a342ff40286215b03bcd5a84e3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/21c554a342ff40286215b03bcd5a84e3?s=96&d=mm&r=g","caption":"Nguyen Thuy"},"url":"https:\/\/techmaster.com.vn\/en\/author\/mimi2021\/"},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/techmaster.com.vn\/en\/temperature-and-humidity-meter-calibration\/#local-main-organization-logo","url":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png","contentUrl":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png","width":335,"height":62,"caption":"Techmaster Electronics JSC"}]}},"_links":{"self":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/posts\/40573","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/comments?post=40573"}],"version-history":[{"count":0,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/posts\/40573\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/media\/47651"}],"wp:attachment":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/media?parent=40573"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/categories?post=40573"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/tags?post=40573"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}