{"id":40259,"date":"2022-09-14T14:15:51","date_gmt":"2022-09-14T07:15:51","guid":{"rendered":"https:\/\/techmaster.com.vn\/?p=40259"},"modified":"2022-12-27T16:37:28","modified_gmt":"2022-12-27T09:37:28","slug":"force-gauge-calibration","status":"publish","type":"post","link":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/","title":{"rendered":"Force Gauge Calibration"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-47742\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg\" alt=\"Force Gauge Calibration\" width=\"1440\" height=\"795\" \/><\/a><\/p>\n<p><span style=\"color: #000000;\">Force Gauge Calibration in Techmaster<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">A force gauge is a device used for force test requirements. This instrument is commonly used in research and development, laboratory, quality, manufacturing and field environments. Therefore, for manufacturing industries such as garment industry, footwear industry, sports equipment manufacturing, electronic components production &#8230; this is an important measuring device.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">So, calibration of the force gauge will ensure stable and accurate operation of the device. Detect the risks of damage to this equipment early, for the most reliable measurement results.<\/span><\/p>\n<h2><span style=\"color: #000000;\"><strong>1. What is force gauge ?<\/strong><\/span><\/h2>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">Force gauge is a small measuring instrument to measure force, known as \u201cpush pull gauge\u201d or \u201cpush pull scale.\u201d As the names suggest, force gauge measures push force (compression) and pull force (tension). However, force gauge also measures various force such as adhesion, peel force, COF and more in combination with a desired attachment. Force gauge can be used as a simple handheld measuring device, or as an accurate force tester in combination with a dedicated test stand.<\/span><\/p>\n<p><span style=\"color: #000000;\">Force gauges are roughly divided into 2 types: Digital force gauge, which has a load cell built-in. And mechanical force gauge, which has a spring mechanism.<\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"color: #000000;\"><a style=\"color: #000000;\" href=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/11\/hieu-chuan-dong-ho-do-luc-gioi-thieu.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-24643\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/11\/hieu-chuan-dong-ho-do-luc-gioi-thieu.jpg\" alt=\"\u0110\u1ed3ng h\u1ed3 \u0111o l\u1ef1c - l\u1ef1c k\u1ebf (force gauge) l\u00e0 g\u00ec ?\" width=\"772\" height=\"346\" \/><\/a><\/span><\/p>\n<h2><span style=\"color: #000000;\"><strong>2. Applications<\/strong><\/span><\/h2>\n<div class=\"FFpbKc\">\n<div><span style=\"color: #000000;\">Force is one of the physical factors that are almost easily encountered in life as well as in production. Therefore, force gauges are popular measuring devices in many fields from research, production and quality assessment of finished products.<\/span><\/div>\n<div><\/div>\n<div><span style=\"color: #000000;\">Some of the applications include:<\/span><\/div>\n<div>\n<p><span style=\"color: #000000;\">&#8211; Test the pull force of garments such as backpacks, bags, etc.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Test the pull force of clothes button for products in the garment industry<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Test the compression of sports equipment products such as tennis balls, etc.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Check the pull force acting on rolling doors, sliding doors, etc<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Safety testing of products using force factors, etc<\/span><\/p>\n<p><span style=\"color: #000000;\">And there are many other measurement applications.<\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"color: #000000;\"><a style=\"color: #000000;\" href=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/11\/hieu-chuan-dong-ho-do-luc-mot-so-ung-dung.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-24656\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/11\/hieu-chuan-dong-ho-do-luc-mot-so-ung-dung.jpg\" alt=\"Hi\u1ec7u chu\u1ea9n \u0111\u1ed3ng h\u1ed3 \u0111o l\u1ef1c v\u1edbi c\u00e1c \u1ee9ng d\u1ee5ng\" width=\"746\" height=\"424\" \/><\/a><\/span><\/p>\n<h2><span style=\"color: #000000;\"><strong style=\"font-size: 23.04px;\">3. Force Gauge Calibration Process<\/strong><\/span><\/h2>\n<div style=\"text-align: justify;\">\n<h3><span style=\"color: #000000;\"><strong>3.1 Why Force Gauge Calibration?<\/strong><\/span><\/h3>\n<p><span style=\"color: #000000;\">Force Gauge is an important measuring device that requires high accuracy. Therefore, calibration of this device is extremely necessary. As it will help ensure stability and accuracy for related operations. Besides, the calibration also helps to detect equipment failures (if any) early for timely correction and repair.<\/span><\/p>\n<p style=\"text-align: center;\"><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/kEvEO8_cmaU\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<h3><span style=\"color: #000000;\"><strong>3.2 Calibration instrument<\/strong><\/span><\/h3>\n<div>\n<p><span style=\"color: #000000;\">&#8211; Standard Weight Set up to 100kg total weight, class F2 or above.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Force calibrator or Standard Loadcell, accuracy better than 3 times Unit Under Test (UUT).<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211;\u00a0 Hanging fixture for hang weight test, or clamp, connector tools, stand base for loadcell and force calibrator.<\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"color: #000000;\"><a style=\"color: #000000;\" href=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/11\/phuong-tien-hieu-chuan-dong-ho-do-luc-2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-24673\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/11\/phuong-tien-hieu-chuan-dong-ho-do-luc-2.jpg\" alt=\"Ph\u01b0\u01a1ng ti\u1ec7n hi\u1ec7u chu\u1ea9n \u0111\u1ed3ng h\u1ed3 \u0111o l\u1ef1c-l\u1ef1c k\u1ebf - force gauge\" width=\"755\" height=\"425\" \/><\/a><\/span><\/p>\n<\/div>\n<div>\n<h3><span style=\"color: #000000;\"><strong>3.3 Environment conditions<\/strong><\/span><\/h3>\n<p><span style=\"color: #000000;\">&#8211; Temperature:\u00a0 (19 \u00b1 2)\u00baC<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Relative Humidity: (20 \u00f7 65)%RH<\/span><\/p>\n<p><span style=\"color: #000000;\"><em><strong>Note:<\/strong> environment conditions above apply for Techmaster inhouse laboratories. Outside this bound conditions will be considered with customer for uncertainty and measurement results.<\/em><\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"color: #000000;\"><a style=\"color: #000000;\" href=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/11\/dieu-kien-hieu-chuan-dong-ho-do-luc.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-24682\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/11\/dieu-kien-hieu-chuan-dong-ho-do-luc.jpg\" alt=\"\u0110i\u1ec1u ki\u1ec7n hi\u1ec7u chu\u1ea9n \u0111\u1ed3ng h\u1ed3 \u0111o l\u1ef1c\" width=\"755\" height=\"425\" \/><\/a><\/span><\/p>\n<h3><span style=\"color: #000000;\"><strong>3.4 Preparation<\/strong><\/span><\/h3>\n<\/div>\n<div>\n<p><span style=\"color: #000000;\">&#8211; Visually inspect the UUT for obvious damage that may affect accuracy and\/or operation and note any observations.\u00a0<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">&#8211; Technician must be familiar with calibration techniques and the operator manual of the UUT being calibrated.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #000000;\">&#8211; Connect UUT and standard meter to suitable power, switch on and warm up at least 30 minutes or follow manufacturer\u2019s manual.\u00a0<\/span><\/p>\n<h3><span style=\"color: #000000;\"><strong>3.5 Perform<\/strong><\/span><\/h3>\n<p><span style=\"color: #000000;\">Calibration points will be perform at approximately 20%, 40%, 60%, 80% and 95% (or 100%) of UUT range. Test point at 100% UUT range may not possible depend on overload range of UUT, when the mass of hanging weight may affect at that test point.\u00a0<\/span><\/p>\n<p><span style=\"color: #000000;\">Other test point of UUT range can be done follow customer\u2019s requirements.<\/span><\/p>\n<h4><span style=\"color: #000000;\"><strong>3.5.1 Hang weight method<\/strong><\/span><\/h4>\n<p><span style=\"color: #000000;\">&#8211; Mount UUT downward (pull or tension direction) on clamp fixture, set zero on UUT<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Select amount of weights at 20% UUT range, hang weights at the pull hook on UUT.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Waiting for stable reading, record reading values, repeat 5 times.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Increase load weight and repeat for remains test points.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Remove weights, change UUT to upward, clamp on fixture.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Place hang fixture on top of push connector of UUT, set zero on UUT.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Select amount of weights at 20% UUT range, hang weights at the fixture.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Record reading values, repeat for remain test points.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Calibration completed, remove all hang weight and fixture from UUT, secure all equipment.<\/span><\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/11\/ghi-nhan-ket-qua-20-hieu-chuan-dong-ho-do-luc.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-24699\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/11\/ghi-nhan-ket-qua-20-hieu-chuan-dong-ho-do-luc.jpg\" alt=\"Ghi nh\u1eadn k\u1ebft qu\u1ea3 \u0111o m\u1ee9c t\u1ea3i 20%\" width=\"755\" height=\"425\" \/><\/a><\/p>\n<h4><span style=\"color: #000000;\"><strong>3.5.2 Loadcell method<\/strong><\/span><\/h4>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><span style=\"color: #000000;\">&#8211; When calibrated using force calibrator or load cell system, connect UUT to standard equipment by suitable connector.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Exercise applied force for UUT three times, to Full Scale or calibrated range before official measurement.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Set zero on UUT and standard load cell or force calibrator.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Apply tension force at appropriate 20%UUT range, compare reading values on UUT and standard equipment.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Record reading values, repeat for remain test points.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Change UUT to opposite direction if have, repeat for compression direction.<\/span><\/p>\n<p><span style=\"color: #000000;\">&#8211; Calibration completed, remove all connectors and fixture from UUT, and secure all equipment.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; Force Gauge Calibration in Techmaster A force gauge is a device used for force test requirements. This instrument is commonly used in research and development, laboratory, quality, manufacturing and field environments. Therefore, for manufacturing industries such as garment industry, footwear industry, sports equipment manufacturing, electronic components production &#8230; this is an important measuring device. [&#8230;]\n","protected":false},"author":4,"featured_media":47742,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[62,456],"tags":[],"class_list":["post-40259","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bai-viet-moi","category-calibration-process"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.8 (Yoast SEO v26.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Force Gauge Calibration - Techmaster Electronics JSC<\/title>\n<meta name=\"description\" content=\"Force Gauge Calibration is extremely necessary. As it will help ensure stability and accuracy for related operations. Force Gauge Calibration Process.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Force Gauge Calibration\" \/>\n<meta property=\"og:description\" content=\"Force Gauge Calibration is extremely necessary. As it will help ensure stability and accuracy for related operations. Force Gauge Calibration Process.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/\" \/>\n<meta property=\"og:site_name\" content=\"Techmaster Electronics JSC\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/techmaster.electronics.jsc\" \/>\n<meta property=\"article:published_time\" content=\"2022-09-14T07:15:51+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-12-27T09:37:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1440\" \/>\n\t<meta property=\"og:image:height\" content=\"795\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@techmastervn\" \/>\n<meta name=\"twitter:site\" content=\"@techmastervn\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/d8c958de5e0f4e5f153c75d77e77654b\"},\"headline\":\"Force Gauge Calibration\",\"datePublished\":\"2022-09-14T07:15:51+00:00\",\"dateModified\":\"2022-12-27T09:37:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/\"},\"wordCount\":765,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg\",\"articleSection\":[\"B\u00e0i vi\u1ebft m\u1edbi\",\"Calibration Process\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#respond\"]}],\"copyrightYear\":\"2022\",\"copyrightHolder\":{\"@id\":\"https:\/\/techmaster.com.vn\/#organization\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/\",\"url\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/\",\"name\":\"Force Gauge Calibration - Techmaster Electronics JSC\",\"isPartOf\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg\",\"datePublished\":\"2022-09-14T07:15:51+00:00\",\"dateModified\":\"2022-12-27T09:37:28+00:00\",\"description\":\"Force Gauge Calibration is extremely necessary. As it will help ensure stability and accuracy for related operations. Force Gauge Calibration Process.\",\"breadcrumb\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#primaryimage\",\"url\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg\",\"contentUrl\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg\",\"width\":1440,\"height\":795,\"caption\":\"Force Gauge Calibration\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Trang ch\u1ee7\",\"item\":\"https:\/\/techmaster.com.vn\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Force Gauge Calibration\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/#website\",\"url\":\"https:\/\/techmaster.com.vn\/en\/\",\"name\":\"Techmaster Electronics JSC\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/techmaster.com.vn\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Organization\",\"Place\"],\"@id\":\"https:\/\/techmaster.com.vn\/en\/#organization\",\"name\":\"Techmaster Electronics JSC\",\"url\":\"https:\/\/techmaster.com.vn\/en\/\",\"logo\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#local-main-organization-logo\"},\"image\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#local-main-organization-logo\"},\"sameAs\":[\"https:\/\/www.facebook.com\/techmaster.electronics.jsc\",\"https:\/\/x.com\/techmastervn\",\"https:\/\/www.instagram.com\/techmastervietnam\",\"https:\/\/myspace.com\/techmastervietnam\",\"https:\/\/www.youtube.com\/c\/TechmasterElectronicsJSC\",\"https:\/\/www.pinterest.com\/techmasterelectronicsjsc\/\",\"https:\/\/vi.wikipedia.org\/wiki\/Th\u00e0nh_vi\u00ean:Techmastervietnam\",\"https:\/\/twitter.com\/techmastervn\",\"https:\/\/www.linkedin.com\/company\/techmaster-vietnam\/\"],\"telephone\":[],\"contactPoint\":{\"@type\":\"ContactPoint\",\"email\":\"marketing@techmaster.com.vn\"},\"openingHoursSpecification\":[{\"@type\":\"OpeningHoursSpecification\",\"dayOfWeek\":[\"Monday\",\"Tuesday\",\"Wednesday\",\"Thursday\",\"Friday\",\"Saturday\",\"Sunday\"],\"opens\":\"09:00\",\"closes\":\"17:00\"}],\"email\":\"marketing@techmaster.com.vn\",\"areaServed\":\"Vietnam\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/d8c958de5e0f4e5f153c75d77e77654b\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/306d1144d12d6aca3985e2faca8b6771?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/306d1144d12d6aca3985e2faca8b6771?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"url\":\"https:\/\/techmaster.com.vn\/en\/author\/admin\/\"},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#local-main-organization-logo\",\"url\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png\",\"contentUrl\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png\",\"width\":335,\"height\":62,\"caption\":\"Techmaster Electronics JSC\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Force Gauge Calibration - Techmaster Electronics JSC","description":"Force Gauge Calibration is extremely necessary. As it will help ensure stability and accuracy for related operations. Force Gauge Calibration Process.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/","og_locale":"en_US","og_type":"article","og_title":"Force Gauge Calibration","og_description":"Force Gauge Calibration is extremely necessary. As it will help ensure stability and accuracy for related operations. Force Gauge Calibration Process.","og_url":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/","og_site_name":"Techmaster Electronics JSC","article_publisher":"https:\/\/www.facebook.com\/techmaster.electronics.jsc","article_published_time":"2022-09-14T07:15:51+00:00","article_modified_time":"2022-12-27T09:37:28+00:00","og_image":[{"width":1440,"height":795,"url":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_creator":"@techmastervn","twitter_site":"@techmastervn","twitter_misc":{"Written by":"admin","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#article","isPartOf":{"@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/"},"author":{"name":"admin","@id":"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/d8c958de5e0f4e5f153c75d77e77654b"},"headline":"Force Gauge Calibration","datePublished":"2022-09-14T07:15:51+00:00","dateModified":"2022-12-27T09:37:28+00:00","mainEntityOfPage":{"@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/"},"wordCount":765,"commentCount":0,"publisher":{"@id":"https:\/\/techmaster.com.vn\/en\/#organization"},"image":{"@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#primaryimage"},"thumbnailUrl":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg","articleSection":["B\u00e0i vi\u1ebft m\u1edbi","Calibration Process"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#respond"]}],"copyrightYear":"2022","copyrightHolder":{"@id":"https:\/\/techmaster.com.vn\/#organization"}},{"@type":"WebPage","@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/","url":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/","name":"Force Gauge Calibration - Techmaster Electronics JSC","isPartOf":{"@id":"https:\/\/techmaster.com.vn\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#primaryimage"},"image":{"@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#primaryimage"},"thumbnailUrl":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg","datePublished":"2022-09-14T07:15:51+00:00","dateModified":"2022-12-27T09:37:28+00:00","description":"Force Gauge Calibration is extremely necessary. As it will help ensure stability and accuracy for related operations. Force Gauge Calibration Process.","breadcrumb":{"@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#primaryimage","url":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg","contentUrl":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/09\/force-gauge-calibration-1.jpg","width":1440,"height":795,"caption":"Force Gauge Calibration"},{"@type":"BreadcrumbList","@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Trang ch\u1ee7","item":"https:\/\/techmaster.com.vn\/en\/"},{"@type":"ListItem","position":2,"name":"Force Gauge Calibration"}]},{"@type":"WebSite","@id":"https:\/\/techmaster.com.vn\/en\/#website","url":"https:\/\/techmaster.com.vn\/en\/","name":"Techmaster Electronics JSC","description":"","publisher":{"@id":"https:\/\/techmaster.com.vn\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/techmaster.com.vn\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Organization","Place"],"@id":"https:\/\/techmaster.com.vn\/en\/#organization","name":"Techmaster Electronics JSC","url":"https:\/\/techmaster.com.vn\/en\/","logo":{"@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#local-main-organization-logo"},"image":{"@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#local-main-organization-logo"},"sameAs":["https:\/\/www.facebook.com\/techmaster.electronics.jsc","https:\/\/x.com\/techmastervn","https:\/\/www.instagram.com\/techmastervietnam","https:\/\/myspace.com\/techmastervietnam","https:\/\/www.youtube.com\/c\/TechmasterElectronicsJSC","https:\/\/www.pinterest.com\/techmasterelectronicsjsc\/","https:\/\/vi.wikipedia.org\/wiki\/Th\u00e0nh_vi\u00ean:Techmastervietnam","https:\/\/twitter.com\/techmastervn","https:\/\/www.linkedin.com\/company\/techmaster-vietnam\/"],"telephone":[],"contactPoint":{"@type":"ContactPoint","email":"marketing@techmaster.com.vn"},"openingHoursSpecification":[{"@type":"OpeningHoursSpecification","dayOfWeek":["Monday","Tuesday","Wednesday","Thursday","Friday","Saturday","Sunday"],"opens":"09:00","closes":"17:00"}],"email":"marketing@techmaster.com.vn","areaServed":"Vietnam"},{"@type":"Person","@id":"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/d8c958de5e0f4e5f153c75d77e77654b","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/techmaster.com.vn\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/306d1144d12d6aca3985e2faca8b6771?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/306d1144d12d6aca3985e2faca8b6771?s=96&d=mm&r=g","caption":"admin"},"url":"https:\/\/techmaster.com.vn\/en\/author\/admin\/"},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/techmaster.com.vn\/en\/force-gauge-calibration\/#local-main-organization-logo","url":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png","contentUrl":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png","width":335,"height":62,"caption":"Techmaster Electronics JSC"}]}},"_links":{"self":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/posts\/40259","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/comments?post=40259"}],"version-history":[{"count":0,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/posts\/40259\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/media\/47742"}],"wp:attachment":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/media?parent=40259"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/categories?post=40259"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/tags?post=40259"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}