{"id":48483,"date":"2023-02-01T14:38:33","date_gmt":"2023-02-01T07:38:33","guid":{"rendered":"https:\/\/techmaster.com.vn\/?page_id=48483"},"modified":"2023-02-01T16:08:52","modified_gmt":"2023-02-01T09:08:52","slug":"portable-particle-counter-lasair-iii","status":"publish","type":"page","link":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/","title":{"rendered":"Portable Particle Counter: Lasair\u00ae III"},"content":{"rendered":"\n\t<section class=\"section\" id=\"section_653138325\">\n\t\t<div class=\"bg section-bg fill bg-fill  \" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-670635821\">\n\n\n\t<div id=\"col-1305252462\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-4138010686\" class=\"text\">\n\t\t\n\n<h2 class=\"banner-title\"><span style=\"font-size: 110%;\">Portable Particle Counter: Lasair\u00ae III<\/span><\/h2>\r\n<h5 class=\"banner-subtitle\"><span style=\"font-size: 110%;\">Proven reliability &#8211; Meets regulatory requirements &#8211; Built to last<\/span><\/h5>\r\n<div id=\"highlighter--hover-tools\" style=\"display: none;\">\r\n<div id=\"highlighter--hover-tools--container\">\r\n<div class=\"highlighter--icon highlighter--icon-copy\" title=\"Copy\">\u00a0<\/div>\r\n<div class=\"highlighter--icon highlighter--icon-change-color\" title=\"Change Color\">\u00a0<\/div>\r\n<div class=\"highlighter--icon highlighter--icon-delete\" title=\"Delete\">\u00a0<\/div>\r\n<\/div>\r\n<\/div>\n\t\t\n<style>\n#text-4138010686 {\n  font-size: 1.7rem;\n  color: rgb(255, 255, 255);\n}\n#text-4138010686 > * {\n  color: rgb(255, 255, 255);\n}\n<\/style>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1305252462 > .col-inner {\n  padding: 0px 0px 0px 10px;\n  margin: 0px 0px -55px 0px;\n}\n@media (min-width:550px) {\n  #col-1305252462 > .col-inner {\n    padding: 0px 0px 0px 40px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_653138325 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n#section_653138325 .section-bg.bg-loaded {\n  background-image: url(https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/07\/banner-liquids.jpeg);\n}\n#section_653138325 .ux-shape-divider--top svg {\n  height: 150px;\n  --divider-top-width: 100%;\n}\n#section_653138325 .ux-shape-divider--bottom svg {\n  height: 150px;\n  --divider-width: 100%;\n}\n<\/style>\n\t<\/section>\n\t\n\t<section class=\"section\" id=\"section_2129228283\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row align-middle\"  id=\"row-1345807312\">\n\n\n\t<div id=\"col-742266806\" class=\"col medium-12 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-2125826579\" class=\"text\">\n\t\t\n\n<h3><em>Array<\/em><\/h3>\r\n<div id=\"highlighter--hover-tools\" style=\"display: none;\">\r\n<div id=\"highlighter--hover-tools--container\">\r\n<div class=\"highlighter--icon highlighter--icon-copy\" title=\"Copy\">\u00a0<\/div>\r\n<div class=\"highlighter--icon highlighter--icon-change-color\" title=\"Change Color\">\u00a0<\/div>\r\n<div class=\"highlighter--icon highlighter--icon-delete\" title=\"Delete\">\u00a0<\/div>\r\n<\/div>\r\n<\/div>\n\t\t\n<style>\n#text-2125826579 {\n  font-size: 1.4rem;\n  color: rgb(0, 149, 157);\n}\n#text-2125826579 > * {\n  color: rgb(0, 149, 157);\n}\n<\/style>\n\t<\/div>\n\t\n\t<div id=\"text-883085638\" class=\"text\">\n\t\t\n\n<div style=\"text-align: left;\">\r\n<h3><span data-text-color=\"alert\"><em>Sets the standard for portable aerosol particle counters and meets the requirements of\u00a0ISO 14644-1:2015\u00a0and\u00a0ISO 21501-4.<\/em><\/span><\/h3>\r\n<p>The Lasair III Aerosol Portable Particle Counter is\u00a0<em><strong>designed for cleanrooms\u00a0<\/strong><\/em>with your unique needs in mind. It sets the standard for portable aerosol particle counters in highly regulated environments, so you can make sure your environment is clean.<\/p>\r\n<p>It can be\u00a0<em><strong>used for both remote and mobile\u00a0<\/strong><\/em>routine cleanroom monitoring. We know the requirements and we\u2019ve done the calculations for you;\u00a0<em><strong>cleanroom certification results\u00a0<\/strong><\/em>are available through a local printout, downloadable via USB in a secure format, or through the use of external software packages, such as\u00a0<span style=\"color: #ed1c24;\">DataAnalyst<\/span>,\u00a0<span style=\"color: #ed1c24;\">FacilityNet<\/span>\u00a0or FacilityNet Pharma Software.<\/p>\r\n<\/div>\r\n<div id=\"highlighter--hover-tools\" style=\"display: none;\">\r\n<div id=\"highlighter--hover-tools--container\">\r\n<div class=\"highlighter--icon highlighter--icon-copy\" title=\"Copy\">\u00a0<\/div>\r\n<div class=\"highlighter--icon highlighter--icon-change-color\" title=\"Change Color\">\u00a0<\/div>\r\n<div class=\"highlighter--icon highlighter--icon-delete\" title=\"Delete\">\u00a0<\/div>\r\n<\/div>\r\n<\/div>\r\n<div id=\"highlighter--hover-tools\" style=\"display: none;\">\r\n<div id=\"highlighter--hover-tools--container\">\r\n<div class=\"highlighter--icon highlighter--icon-copy\" title=\"Copy\">\u00a0<\/div>\r\n<div class=\"highlighter--icon highlighter--icon-change-color\" title=\"Change Color\">\u00a0<\/div>\r\n<div class=\"highlighter--icon highlighter--icon-delete\" title=\"Delete\">\u00a0<\/div>\r\n<\/div>\r\n<\/div>\n\t\t\n<style>\n#text-883085638 {\n  font-size: 1.1rem;\n}\n<\/style>\n\t<\/div>\n\t\n<div class=\"accordion\" rel=\"\">\n\n<div class=\"accordion-item\"><a href=\"#\" class=\"accordion-title plain\"><button class=\"toggle\" aria-label=\"Toggle\"><i class=\"icon-angle-down\"><\/i><\/button><span>Read more<\/span><\/a><div class=\"accordion-inner\">\n\n\t<div id=\"text-1286071105\" class=\"text\">\n\t\t\n\n<p>Power is provided to the unit through the use of the on-board, hot-swappable batteries. Power can also be provided through the use of an external AC power source, which can simultaneously power the unit and charge the on-board batteries.<\/p>\r\n<p>The Lasair III Portable Particle Counter\u00a0<em><strong>accepts inputs from a wide range of environmental sensors<\/strong><\/em>\u00a0through the four built-in 4-20 mA inputs.\u00a0<em><strong>Wireless network communications<\/strong><\/em>\u00a0are made easy with an externally mounted wireless adapter, simplifying communications with network systems.<\/p>\r\n<div id=\"highlighter--hover-tools\" style=\"display: none;\">\r\n<div id=\"highlighter--hover-tools--container\">\r\n<div class=\"highlighter--icon highlighter--icon-copy\" title=\"Copy\">\u00a0<\/div>\r\n<div class=\"highlighter--icon highlighter--icon-change-color\" title=\"Change Color\">\u00a0<\/div>\r\n<div class=\"highlighter--icon highlighter--icon-delete\" title=\"Delete\">\u00a0<\/div>\r\n<\/div>\r\n<\/div>\n\t\t\n<style>\n#text-1286071105 {\n  font-size: 1.1rem;\n}\n<\/style>\n\t<\/div>\n\t\n\n<\/div><\/div>\n\n<\/div>\n<a href=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2023\/02\/lasair-iii-031617.pdf\" target=\"_self\" class=\"button alert is-large\"  >\n    <span>Download Spec Sheet<\/span>\n  <\/a>\n\n\n<a href=\"https:\/\/techmaster.com.vn\/en\/contact\/#request\" target=\"_self\" class=\"button alert is-large\"  >\n    <span>Request a Quote<\/span>\n  <\/a>\n\n\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-742266806 > .col-inner {\n  padding: 0px 0px 0px 0;\n  margin: -6px 0px 0px 0px;\n}\n@media (min-width:850px) {\n  #col-742266806 > .col-inner {\n    padding: 0px 0px 0px 10%;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-1966495336\" class=\"col medium-12 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<div class=\"slider-wrapper relative\" id=\"slider-913961245\" >\n    <div class=\"slider slider-nav-circle slider-nav-large slider-nav-dark slider-style-normal slider-show-nav\"\n        data-flickity-options='{\n            \"cellAlign\": \"center\",\n            \"imagesLoaded\": true,\n            \"lazyLoad\": 1,\n            \"freeScroll\": false,\n            \"wrapAround\": true,\n            \"autoPlay\": false,\n            \"pauseAutoPlayOnHover\" : true,\n            \"prevNextButtons\": true,\n            \"contain\" : true,\n            \"adaptiveHeight\" : true,\n            \"dragThreshold\" : 10,\n            \"percentPosition\": true,\n            \"pageDots\": true,\n            \"rightToLeft\": false,\n            \"draggable\": true,\n            \"selectedAttraction\": 0.1,\n            \"parallax\" : 0,\n            \"friction\": 0.6        }'\n        >\n        \n\n<div class=\"row\"  id=\"row-388101770\">\n\n\n\t<div id=\"col-2071628141\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1061871887\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2023\/02\/Lasair-III-Airborne-Portable-Particle-Counter-WiFI-1.png\" class=\"attachment-large size-large\" alt=\"Lasair III Airborne Portable Particle Counter WiFI\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1061871887 {\n  width: 95%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-2071628141 > .col-inner {\n  padding: 38px 0px 0px 0px;\n  margin: 0px 0px 0px 14px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-1840493622\">\n\n\n\t<div id=\"col-5367663\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_819203338\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" style=\"margin:0px 0px 0px 0px;\">\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/Lasair-III-wifi-with-wifi-stamp-sm.png\" class=\"attachment-large size-large\" alt=\"Lasair III wifi with wifi stamp sm\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_819203338 {\n  width: 95%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-5367663 > .col-inner {\n  padding: 38px 0px 0px 0px;\n  margin: 0px 0px 0px 14px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-2026791309\">\n\n\n\t<div id=\"col-1759809465\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1995664046\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" style=\"margin:0px 0px 0px 0px;\">\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/Lasair-III-wifi-Front.png\" class=\"attachment-large size-large\" alt=\"Lasair III wifi Front\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1995664046 {\n  width: 95%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1759809465 > .col-inner {\n  padding: 38px 0px 0px 0px;\n  margin: 0px 0px 0px 14px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-764163793\">\n\n\n\t<div id=\"col-2023036317\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1714479759\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" style=\"margin:0px 0px 0px 0px;\">\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/Lasair-III-wifi-Back.png\" class=\"attachment-large size-large\" alt=\"Lasair III wifi Back\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1714479759 {\n  width: 95%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-2023036317 > .col-inner {\n  padding: 38px 0px 0px 0px;\n  margin: 0px 0px 0px 14px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-2010949253\">\n\n\n\t<div id=\"col-1156480742\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_1955935695\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2023\/02\/Lasair-III-310C-ISO2.png\" class=\"attachment-large size-large\" alt=\"Lasair III 310C ISO2\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1955935695 {\n  width: 95%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1156480742 > .col-inner {\n  padding: 38px 0px 0px 0px;\n  margin: 0px 0px 0px 14px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n\n     <\/div>\n\n     <div class=\"loading-spin dark large centered\"><\/div>\n\n     \t<\/div>\n\n\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"text-center\"><div class=\"is-divider divider clearfix\" ><\/div><\/div>\n\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_2129228283 {\n  padding-top: 40px;\n  padding-bottom: 40px;\n  background-color: rgb(255,255,255);\n}\n#section_2129228283 .ux-shape-divider--top svg {\n  height: 150px;\n  --divider-top-width: 100%;\n}\n#section_2129228283 .ux-shape-divider--bottom svg {\n  height: 150px;\n  --divider-width: 100%;\n}\n@media (min-width:850px) {\n  #section_2129228283 {\n    padding-top: 70px;\n    padding-bottom: 70px;\n  }\n}\n<\/style>\n\t<\/section>\n\t\n\t<section class=\"section dark\" id=\"section_1709773447\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-2102098567\">\n\n\n\t<div id=\"col-70959745\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<div class=\"row\"  id=\"row-332631691\">\n\n\n\t<div id=\"col-882146192\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-3402216095\" class=\"text\">\n\t\t\n\n<h2 class=\"info-title\" style=\"text-align: left;\"><span data-text-color=\"alert\">Features<\/span><\/h2>\r\n<ul>\r\n<li style=\"text-align: left;\">100 LPM, 50 LPM, or 1 CFM flow rates available<\/li>\r\n<li style=\"text-align: left;\">100 LPM flow samples 1 m<sup>3<\/sup>\u00a0in 10 minutes<\/li>\r\n<li style=\"text-align: left;\">ISO 21501-4 compliant with a built-in pulse height analyzer (PHA). Available with ISO 17025 calibration certificate. (Optional)<\/li>\r\n<li style=\"text-align: left;\">Large, 8.4 inch\u00a0<span data-text-color=\"alert\">IR touchscreen<\/span>\u00a0can be used when wearing gloves for simplified use<\/li>\r\n<li style=\"text-align: left;\">Calculates and creates reports for ISO 14644-1:1999, ISO 14644-1:2015,\u00a0<span data-text-color=\"alert\">EU\u00a0GMP Annex 1<\/span>, China GMP, and FS 209E<\/li>\r\n<li style=\"text-align: left;\">Access via a Web browser<\/li>\r\n<li style=\"text-align: left;\">Compatible with common cleanroom cleaning chemicals<\/li>\r\n<li style=\"text-align: left;\">Choose from 12 languages for display and printout<\/li>\r\n<li style=\"text-align: left;\">EU GMP Annex 1 and IS<\/li>\r\n<\/ul>\n\t\t\n<style>\n#text-3402216095 {\n  color: rgb(0,0,0);\n}\n#text-3402216095 > * {\n  color: rgb(0,0,0);\n}\n<\/style>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1344280423\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-2423099856\" class=\"text\">\n\t\t\n\n<h2 class=\"info-title\" style=\"text-align: left;\"><span data-text-color=\"alert\">Benefits<\/span><\/h2>\r\n<ul>\r\n<li style=\"text-align: left;\">Comprehensive validation manual makes it easy to meet pharmaceutical regulatory requirements<\/li>\r\n<li style=\"text-align: left;\">Operates in cleanrooms via a web browser: Set up, sample, display, print, download data<\/li>\r\n<li style=\"text-align: left;\">Removable\u00a0<span data-text-color=\"alert\">batteries<\/span>\u00a0with optional external charger for continuous mobile use<\/li>\r\n<li style=\"text-align: left;\">Pre-configured\u00a0<span data-text-color=\"alert\">cleanroom sampling recipes<\/span>\u00a0to reduce operator errors<\/li>\r\n<li style=\"text-align: left;\">Long-term data archiving with\u00a0<span data-text-color=\"alert\">DataAnalyst software<\/span><\/li>\r\n<li style=\"text-align: left;\">Local printout for immediate hardcopy results<\/li>\r\n<li style=\"text-align: left;\">USB electronic printouts for long term storage<\/li>\r\n<li style=\"text-align: left;\">WiFi communication for easier data transfer and instrument control (optional)<\/li>\r\n<li style=\"text-align: left;\">CSV file download for easy data integration<\/li>\r\n<li style=\"text-align: left;\">Interactive software steps the user through the\u00a0<span data-text-color=\"alert\">ISO 14644-1<\/span>, EU\u00a0GMP Annex 1, China GMP and FS 209E room certification process<\/li>\r\n<li style=\"text-align: left;\">Up to 32 customizable alarm comments for easier cleanroom problem identification<\/li>\r\n<li style=\"text-align: left;\">Modbus TCP\/IP communication protocol for a wider integration with third party monitoring systems<\/li>\r\n<li style=\"text-align: left;\">Large IR touchscreen for simplified use<\/li>\r\n<li style=\"text-align: left;\">Quiet pump improves work environment<\/li>\r\n<li style=\"text-align: left;\">21 CFR Part 11 compliant download<\/li>\r\n<\/ul>\n\t\t\n<style>\n#text-2423099856 {\n  color: rgb(0,0,0);\n}\n#text-2423099856 > * {\n  color: rgb(0,0,0);\n}\n<\/style>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-378432378\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div id=\"text-3927404068\" class=\"text\">\n\t\t\n\n<h2 class=\"info-title\" style=\"text-align: left;\"><span data-text-color=\"alert\">Applications<\/span><\/h2>\r\n<ul>\r\n<li style=\"text-align: left;\">Cleanroom monitoring<\/li>\r\n<li style=\"text-align: left;\">Facility certification for ISO 14644-1:1999 &amp; 2015, EU\u00a0GMP, China GMP, FS 209E<\/li>\r\n<li style=\"text-align: left;\">Trend analysis<\/li>\r\n<li style=\"text-align: left;\">Statistical process control<\/li>\r\n<li style=\"text-align: left;\">Troubleshooting particle excursions<\/li>\r\n<li style=\"text-align: left;\">Manifold compatible<\/li>\r\n<li style=\"text-align: left;\">Portable or dedicated use<\/li>\r\n<li style=\"text-align: left;\"><span data-text-color=\"alert\">Compressed Gas Monitoring<\/span><\/li>\r\n<\/ul>\n\t\t\n<style>\n#text-3927404068 {\n  color: rgb(0,0,0);\n}\n#text-3927404068 > * {\n  color: rgb(0,0,0);\n}\n<\/style>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-70959745 > .col-inner {\n  margin: -50px 0px -80px 50px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"text-center\"><div class=\"is-divider divider clearfix\" style=\"background-color:rgb(179, 179, 179);\"><\/div><\/div>\n\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1709773447 {\n  padding-top: 0px;\n  padding-bottom: 0px;\n  background-color: rgb(255,255,255);\n}\n#section_1709773447 .ux-shape-divider--top svg {\n  height: 150px;\n  --divider-top-width: 100%;\n}\n#section_1709773447 .ux-shape-divider--bottom svg {\n  height: 150px;\n  --divider-width: 100%;\n}\n<\/style>\n\t<\/section>\n\t\n\t<section class=\"section\" id=\"section_1449805718\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-1895413745\">\n\n\n\t<div id=\"col-1404075949\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<h2 class=\"support-materials-title\"><span data-text-color=\"alert\">Supporting Materials<\/span><\/h2>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1404075949 > .col-inner {\n  padding: 0px 0px 0px 50px;\n  margin: -20px 0px 0px 0px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row align-equal row-box-shadow-3 row-box-shadow-5-hover\"  id=\"row-927280955\">\n\n\n\t<div id=\"col-700069840\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\" style=\"background-color:rgba(214, 223, 224, 0.39);\" >\n\t\t\t\n\t\t\t\n\n<h4 class=\"support-title sheets-title\"><span style=\"color: #0d6d72;\">Application Notes &amp; Brochures<\/span><\/h4>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/differences-in-particle-counter-results-a-practical-guide-to-aerosol-particle-counter-matching\/\">A Practical Guide to Aerosol Particle Counter Matching <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/data-integrity-and-21-cfr-part-11\/\">Data Integrity: Understand and Comply with GMP and FDA Requirements for 21 CFR Part 11 <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/21-cfr-part-11-and-data-integrity\/\">21 CFR Part 11 and Data Integrity FAQ <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/sampling-compressed-gas-with-the-lasair-iii-particle-counter\/\">Sampling Compressed Gas with the Lasair III Particle Counter <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/particle-monitoring-in-helmke-drums\/\">Helmke Drums Particle Monitoring <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<div class=\"accordion\" rel=\"\">\n\n<div class=\"accordion-item\"><a href=\"#\" class=\"accordion-title plain\"><button class=\"toggle\" aria-label=\"Toggle\"><i class=\"icon-angle-down\"><\/i><\/button><span>view all<\/span><\/a><div class=\"accordion-inner\">\n\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/iso-14644-1-cleanroom-classification-monitoring\/\">Cleanroom classification of air cleanliness by particle concentration <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/iso-21501-4-calibration\/\">ISO 21501-4 Calibration <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/particle-counting-technology-guide\/\">Paper Series: Guides to Particle Technology <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/risk-assessment-in-pharmaceutical-steps\/\">Effective Risk Assessment in Pharmaceutical: Steps to Ensuring a Successful Audit <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/improve-yield-and-quality-by-monitoring-particle-contamination-during-optics-manufacturing\/\">Improve yield and quality by monitoring particle contamination during optics manufacturing <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/particle-counter-flow-rate-100-lpm-vs-1-cfm\/\">Airborne Particle Measurements: 100 LPM vs. 1 CFM <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/particle-counter-tubing-particle-transportation\/\">Particle Counter Tubing &amp; Particle Transportation <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/testing-valves-for-particle-generation\/\">Testing Valves for Particle Generation <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/powder-filling-when-and-where-to-monitor\/\">Powder Filling: When and Where to Monitor <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/planning-and-installing-a-facility-monitoring-system\/\">Planning and Installing a Facility Monitoring System <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/choosing-the-most-suitable-particle-sample-point-locations\/\">Selecting The Most Suitable Particle Sample Point Locations In Your Cleanroom <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/selecting-an-airborne-particle-counter\/\">Selecting an Airborne Particle Counter <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/counting-efficiency-and-resolution-in-optical-particle-counters\/\">Counting Efficiency and Resolution in Optical Particle Counters <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n<p><a href=\"https:\/\/techmaster.com.vn\/en\/iso-14644-22015-cleanroom-monitoring\/\">Understanding ISO 14644-2:2015 Cleanroom Monitoring <span data-text-color=\"alert\"><strong>&gt;<\/strong><\/span><\/a><\/p>\n\n<\/div><\/div>\n\n<\/div>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-700069840 > .col-inner {\n  padding: 2px 0px 29px 5px;\n  margin: 0px 0px 0px 5px;\n}\n@media (min-width:550px) {\n  #col-700069840 > .col-inner {\n    padding: 22px 0px 0px 15px;\n    margin: 0px 0px 0px 50px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-661941198\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\" style=\"background-color:rgba(214, 223, 224, 0.39);\" >\n\t\t\t\n\t\t\t\n\n<h4><span style=\"color: #0d6d72;\">Webinars<\/span><\/h4>\n<div id=\"highlighter--hover-tools\" style=\"display: none;\">\n<div id=\"highlighter--hover-tools--container\">\n<div class=\"highlighter--icon highlighter--icon-copy\" title=\"Copy\">\u00a0<\/div>\n<div class=\"highlighter--icon highlighter--icon-change-color\" title=\"Change Color\">\u00a0<\/div>\n<div class=\"highlighter--icon highlighter--icon-delete\" title=\"Delete\">\u00a0<\/div>\n<\/div>\n<\/div>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-661941198 > .col-inner {\n  padding: 22px 0px 0px 15px;\n  margin: 0px 0px 0px 5px;\n}\n@media (min-width:550px) {\n  #col-661941198 > .col-inner {\n    margin: 0px 0px 0px 39px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"text-center\"><div class=\"is-divider divider clearfix\" ><\/div><\/div>\n\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1449805718 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n  background-color: rgb(255,255,255);\n}\n#section_1449805718 .ux-shape-divider--top svg {\n  height: 150px;\n  --divider-top-width: 100%;\n}\n#section_1449805718 .ux-shape-divider--bottom svg {\n  height: 150px;\n  --divider-width: 100%;\n}\n<\/style>\n\t<\/section>\n\t\n\t<section class=\"section\" id=\"section_1645413867\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-1215622241\">\n\n\n\t<div id=\"col-225876128\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<h2 class=\"accessories-title\"><span data-text-color=\"alert\">Available Accessories<\/span><\/h2>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-225876128 > .col-inner {\n  padding: 0px 0px 0px 50px;\n  margin: -50px 0px 0px 0px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"row\"  id=\"row-1708578752\">\n\n\n\t<div id=\"col-1344685190\" class=\"col medium-3 small-6 large-3\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" style=\"width:65%;\">\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"154\" height=\"123\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/printer-paper.jpeg\" class=\"attachment- size-\" alt=\"printer paper\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n\n\t<div id=\"gap-73484897\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-73484897 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n\n<h4 class=\"accessory-title\" style=\"text-align: left;\"><span style=\"color: #0d6d72;\">Printer Paper<\/span><\/h4>\n<div class=\"accessory-text\">\n<p style=\"text-align: left;\">Printer Paper is for use with standard printers, as well as for cleanroom-appropriate devices.<\/p>\n<\/div>\n\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1344685190 > .col-inner {\n  margin: 0px 0px 0px 5px;\n}\n@media (min-width:550px) {\n  #col-1344685190 > .col-inner {\n    margin: 1px 0px 0px 50px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-1348244668\" class=\"col medium-3 small-6 large-3\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" style=\"width:65%;\">\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"154\" height=\"124\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/spare-lithium-battery.jpeg\" class=\"attachment- size-\" alt=\"spare lithium battery\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n\n\t<div id=\"gap-1258693005\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1258693005 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n\n<h4 class=\"accessory-title\" style=\"text-align: left;\"><span style=\"color: #0d6d72;\">Spare Lithium Battery<\/span><\/h4>\n<div class=\"accessory-text\">\n<p style=\"text-align: left;\">The Spare Lithium Battery is to keep on hand for replacement power as needed. Also available as a four-pack.<\/p>\n<\/div>\n\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1348244668 > .col-inner {\n  margin: 0px 0px 0px 5px;\n}\n@media (min-width:550px) {\n  #col-1348244668 > .col-inner {\n    margin: 0px 0px 0px 15px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-1305156920\" class=\"col medium-3 small-6 large-3\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" style=\"width:70%;\">\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"154\" height=\"123\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/07\/facilitynet-acc.jpeg\" class=\"attachment- size-\" alt=\"Facility Net\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n\n\t<div id=\"gap-1930194458\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1930194458 {\n  padding-top: 20px;\n}\n<\/style>\n\t<\/div>\n\t\n\n<h4 class=\"accessory-title\" style=\"text-align: left;\"><span style=\"color: #006d72;\">Facility Net<\/span><\/h4>\n<div class=\"accessory-text\">\n<p style=\"text-align: left;\">Facility Net Software provides a solution for comprehensive environmental monitoring, including a real-time and historical data display. Compatible with Particle Measuring Systems particle counters and molecular contamination monitors, as well as various third-party products.<\/p>\n<\/div>\n\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1305156920 > .col-inner {\n  margin: 0px 0px 0px 5px;\n}\n@media (min-width:550px) {\n  #col-1305156920 > .col-inner {\n    margin: 0px 0px 0px 0px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-75138909\" class=\"col medium-3 small-6 large-3\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" style=\"width:75%;\">\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1800\" height=\"984\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/HPD-III-web-optimized-1.jpeg\" class=\"attachment- size-\" alt=\"High-Pressure Diffuser (0.1 CFM)\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n\n\t<div id=\"gap-380368742\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-380368742 {\n  padding-top: 25px;\n}\n<\/style>\n\t<\/div>\n\t\n\n<div class=\"accessory-text\">\n<h4 class=\"accessory-title\" style=\"text-align: left;\"><span style=\"color: #0d6d72;\">High-Pressure Diffuser (0.1 CFM)<\/span><\/h4>\n<div class=\"accessory-text\">\n<p style=\"text-align: left;\">The High-Pressure Diffuser lets you count particles in high-pressure gas lines by taking gas at pressures between 40 and 100psi and reducing it to a level acceptable to particle counters designed for atmospheric pressure.<\/p>\n<\/div>\n<\/div>\n\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-75138909 > .col-inner {\n  margin: 0px 0px 0px -11px;\n}\n@media (min-width:550px) {\n  #col-75138909 > .col-inner {\n    margin: 30px 0px 0px 0px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\t<div id=\"col-864350383\" class=\"col medium-3 small-6 large-3\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" style=\"width:60%;\">\n\t\t\t\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"130\" height=\"116\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/hhipa_011411_web-e1449010246932.jpeg\" class=\"attachment- size-\" alt=\"hand held\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n\n\t<div id=\"gap-1315050739\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1315050739 {\n  padding-top: 19px;\n}\n<\/style>\n\t<\/div>\n\t\n\n<h4 class=\"accessory-title\" style=\"text-align: left;\"><span style=\"color: #0d6d72;\">Hand-Held Isokenetic Sampling Probe<\/span><\/h4>\n<div class=\"accessory-text\">\n<p style=\"text-align: left;\">The Hand-Held Isokenetic Sampling Probe works in conjunction with a 1CFM LASAIR III Particle Counter isokinetic in 90FPM airflow.<\/p>\n<\/div>\n\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-864350383 > .col-inner {\n  margin: 0px 0px 0px 5px;\n}\n@media (min-width:550px) {\n  #col-864350383 > .col-inner {\n    margin: 0px 0px 0px 50px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"text-center\"><div class=\"is-divider divider clearfix\" ><\/div><\/div>\n\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1645413867 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n  background-color: rgb(255,255,255);\n}\n#section_1645413867 .ux-shape-divider--top svg {\n  height: 150px;\n  --divider-top-width: 100%;\n}\n#section_1645413867 .ux-shape-divider--bottom svg {\n  height: 150px;\n  --divider-width: 100%;\n}\n<\/style>\n\t<\/section>\n\t\n\t<section class=\"section\" id=\"section_1242864400\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-1965639356\">\n\n\n\t<div id=\"col-1957458543\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<h2 class=\"related-products-title\"><span data-text-color=\"alert\">Related Products<\/span><\/h2>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1957458543 > .col-inner {\n  margin: -75px 0px 0px 50px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n\t<div id=\"gap-1740010382\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1740010382 {\n  padding-top: 30px;\n}\n<\/style>\n\t<\/div>\n\t\n\n<div class=\"row\"  id=\"row-333485937\">\n\n\n\t<div id=\"col-1111140912\" class=\"col medium-11 small-12 large-11\"  >\n\t\t\t\t<div class=\"col-inner\" style=\"background-color:rgb(255,255,255);\" >\n\t\t\t\n\t\t\t\n\n<div class=\"row row-collapse align-equal\"  id=\"row-1648222385\">\n\n\n\t<div id=\"col-1979480569\" class=\"col medium-12 small-12 large-3\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"box has-hover   has-hover box-text-bottom\" >\n\n\t\t<div class=\"box-image\" style=\"width:75%;\">\n\t\t\t<a href=\"https:\/\/techmaster.com.vn\/en\/0-1-micron-particle-counter-lasair-iii-110\/\"  >\t\t\t<div class=\"\" >\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"380\" height=\"400\" src=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/lasair-iii-110.png\" class=\"attachment- size-\" alt=\"0.1 Micron Particle Counter: Lasair\u00ae III 110\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<\/a>\t\t<\/div>\n\n\t\t<div class=\"box-text text-center\" >\n\t\t\t<div class=\"box-text-inner\">\n\t\t\t\t\n\n\t<div id=\"gap-1400517318\" class=\"gap-element clearfix\" style=\"display:block; height:auto;\">\n\t\t\n<style>\n#gap-1400517318 {\n  padding-top: 10px;\n}\n@media (min-width:550px) {\n  #gap-1400517318 {\n    padding-top: 36px;\n  }\n}\n<\/style>\n\t<\/div>\n\t\n\n<h3 class=\"banner-title\" style=\"text-align: left;\"><a href=\"https:\/\/techmaster.com.vn\/en\/0-1-micron-particle-counter-lasair-iii-110\/\"><span data-text-color=\"alert\">0.1 Micron Particle Counter: Lasair\u00ae III 110<\/span><\/a><\/h3>\n<p style=\"text-align: left;\"><em><strong>The only true .1 micron particle counter<\/strong><\/em>, providing\u00a0<em><strong>real-time measurement<\/strong><\/em> of yield-impacting cleanroom particles with three configurations.<\/p>\n\n\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1979480569 > .col-inner {\n  padding: 0px 0px 0px 0px;\n  margin: 7px 0px 0px 0px;\n}\n<\/style>\n\t<\/div>\n\n\t\n\n\n<style>\n#row-1648222385 > .col > .col-inner {\n  background-color: rgb(255, 255, 255);\n}\n<\/style>\n<\/div>\n\n\t\t<\/div>\n\t\t\t\t\n<style>\n#col-1111140912 > .col-inner {\n  padding: 0px 0px 0px 0px;\n  margin: 0px 0px 0px 10px;\n}\n@media (min-width:550px) {\n  #col-1111140912 > .col-inner {\n    margin: -75px 0px 0px 50px;\n  }\n}\n<\/style>\n\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1242864400 {\n  padding-top: 60px;\n  padding-bottom: 60px;\n  background-color: rgb(255,255,255);\n}\n#section_1242864400 .ux-shape-divider--top svg {\n  height: 150px;\n  --divider-top-width: 100%;\n}\n#section_1242864400 .ux-shape-divider--bottom svg {\n  height: 150px;\n  --divider-width: 100%;\n}\n<\/style>\n\t<\/section>\n\t\n\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":11,"featured_media":44498,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-48483","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.8 (Yoast SEO v26.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Portable Particle Counter: Lasair\u00ae III - Techmaster Electronics JSC<\/title>\n<meta name=\"description\" content=\"The Lasair\u00ae\u00a0III Aerosol Portable Particle Counter sets the standard for portable aerosol particle counters in highly regulated environments\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Portable Particle Counter: Lasair\u00ae III\" \/>\n<meta property=\"og:description\" content=\"The Lasair\u00ae\u00a0III Aerosol Portable Particle Counter sets the standard for portable aerosol particle counters in highly regulated environments\" \/>\n<meta property=\"og:url\" content=\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/\" \/>\n<meta property=\"og:site_name\" content=\"Techmaster Electronics JSC\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/techmaster.electronics.jsc\" \/>\n<meta property=\"article:modified_time\" content=\"2023-02-01T09:08:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/Lasair-III-wifi-with-wifi-stamp-sm.png\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@techmastervn\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/\",\"url\":\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/\",\"name\":\"Portable Particle Counter: Lasair\u00ae III - Techmaster Electronics JSC\",\"isPartOf\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/Lasair-III-wifi-with-wifi-stamp-sm.png\",\"datePublished\":\"2023-02-01T07:38:33+00:00\",\"dateModified\":\"2023-02-01T09:08:52+00:00\",\"description\":\"The Lasair\u00ae\u00a0III Aerosol Portable Particle Counter sets the standard for portable aerosol particle counters in highly regulated environments\",\"breadcrumb\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#primaryimage\",\"url\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/Lasair-III-wifi-with-wifi-stamp-sm.png\",\"contentUrl\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/Lasair-III-wifi-with-wifi-stamp-sm.png\",\"width\":600,\"height\":400,\"caption\":\"Lasair III wifi with wifi stamp sm\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Trang ch\u1ee7\",\"item\":\"https:\/\/techmaster.com.vn\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Portable Particle Counter: Lasair\u00ae III\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/#website\",\"url\":\"https:\/\/techmaster.com.vn\/en\/\",\"name\":\"Techmaster Electronics JSC\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/techmaster.com.vn\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Organization\",\"Place\"],\"@id\":\"https:\/\/techmaster.com.vn\/en\/#organization\",\"name\":\"Techmaster Electronics JSC\",\"url\":\"https:\/\/techmaster.com.vn\/en\/\",\"logo\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#local-main-organization-logo\"},\"image\":{\"@id\":\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#local-main-organization-logo\"},\"sameAs\":[\"https:\/\/www.facebook.com\/techmaster.electronics.jsc\",\"https:\/\/x.com\/techmastervn\",\"https:\/\/www.instagram.com\/techmastervietnam\",\"https:\/\/myspace.com\/techmastervietnam\",\"https:\/\/www.youtube.com\/c\/TechmasterElectronicsJSC\",\"https:\/\/www.pinterest.com\/techmasterelectronicsjsc\/\",\"https:\/\/vi.wikipedia.org\/wiki\/Th\u00e0nh_vi\u00ean:Techmastervietnam\",\"https:\/\/twitter.com\/techmastervn\",\"https:\/\/www.linkedin.com\/company\/techmaster-vietnam\/\"],\"telephone\":[],\"contactPoint\":{\"@type\":\"ContactPoint\",\"email\":\"marketing@techmaster.com.vn\"},\"openingHoursSpecification\":[{\"@type\":\"OpeningHoursSpecification\",\"dayOfWeek\":[\"Monday\",\"Tuesday\",\"Wednesday\",\"Thursday\",\"Friday\",\"Saturday\",\"Sunday\"],\"opens\":\"09:00\",\"closes\":\"17:00\"}],\"email\":\"marketing@techmaster.com.vn\",\"areaServed\":\"Vietnam\"},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#local-main-organization-logo\",\"url\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png\",\"contentUrl\":\"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png\",\"width\":335,\"height\":62,\"caption\":\"Techmaster Electronics JSC\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Portable Particle Counter: Lasair\u00ae III - Techmaster Electronics JSC","description":"The Lasair\u00ae\u00a0III Aerosol Portable Particle Counter sets the standard for portable aerosol particle counters in highly regulated environments","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/","og_locale":"en_US","og_type":"article","og_title":"Portable Particle Counter: Lasair\u00ae III","og_description":"The Lasair\u00ae\u00a0III Aerosol Portable Particle Counter sets the standard for portable aerosol particle counters in highly regulated environments","og_url":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/","og_site_name":"Techmaster Electronics JSC","article_publisher":"https:\/\/www.facebook.com\/techmaster.electronics.jsc","article_modified_time":"2023-02-01T09:08:52+00:00","og_image":[{"width":600,"height":400,"url":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/Lasair-III-wifi-with-wifi-stamp-sm.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_site":"@techmastervn","twitter_misc":{"Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/","url":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/","name":"Portable Particle Counter: Lasair\u00ae III - Techmaster Electronics JSC","isPartOf":{"@id":"https:\/\/techmaster.com.vn\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#primaryimage"},"image":{"@id":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#primaryimage"},"thumbnailUrl":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/Lasair-III-wifi-with-wifi-stamp-sm.png","datePublished":"2023-02-01T07:38:33+00:00","dateModified":"2023-02-01T09:08:52+00:00","description":"The Lasair\u00ae\u00a0III Aerosol Portable Particle Counter sets the standard for portable aerosol particle counters in highly regulated environments","breadcrumb":{"@id":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#primaryimage","url":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/Lasair-III-wifi-with-wifi-stamp-sm.png","contentUrl":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2022\/11\/Lasair-III-wifi-with-wifi-stamp-sm.png","width":600,"height":400,"caption":"Lasair III wifi with wifi stamp sm"},{"@type":"BreadcrumbList","@id":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Trang ch\u1ee7","item":"https:\/\/techmaster.com.vn\/en\/"},{"@type":"ListItem","position":2,"name":"Portable Particle Counter: Lasair\u00ae III"}]},{"@type":"WebSite","@id":"https:\/\/techmaster.com.vn\/en\/#website","url":"https:\/\/techmaster.com.vn\/en\/","name":"Techmaster Electronics JSC","description":"","publisher":{"@id":"https:\/\/techmaster.com.vn\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/techmaster.com.vn\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Organization","Place"],"@id":"https:\/\/techmaster.com.vn\/en\/#organization","name":"Techmaster Electronics JSC","url":"https:\/\/techmaster.com.vn\/en\/","logo":{"@id":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#local-main-organization-logo"},"image":{"@id":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#local-main-organization-logo"},"sameAs":["https:\/\/www.facebook.com\/techmaster.electronics.jsc","https:\/\/x.com\/techmastervn","https:\/\/www.instagram.com\/techmastervietnam","https:\/\/myspace.com\/techmastervietnam","https:\/\/www.youtube.com\/c\/TechmasterElectronicsJSC","https:\/\/www.pinterest.com\/techmasterelectronicsjsc\/","https:\/\/vi.wikipedia.org\/wiki\/Th\u00e0nh_vi\u00ean:Techmastervietnam","https:\/\/twitter.com\/techmastervn","https:\/\/www.linkedin.com\/company\/techmaster-vietnam\/"],"telephone":[],"contactPoint":{"@type":"ContactPoint","email":"marketing@techmaster.com.vn"},"openingHoursSpecification":[{"@type":"OpeningHoursSpecification","dayOfWeek":["Monday","Tuesday","Wednesday","Thursday","Friday","Saturday","Sunday"],"opens":"09:00","closes":"17:00"}],"email":"marketing@techmaster.com.vn","areaServed":"Vietnam"},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/techmaster.com.vn\/en\/portable-particle-counter-lasair-iii\/#local-main-organization-logo","url":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png","contentUrl":"https:\/\/techmaster.com.vn\/wp-content\/uploads\/2021\/04\/techmaster-logo-homepage.png","width":335,"height":62,"caption":"Techmaster Electronics JSC"}]}},"_links":{"self":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/pages\/48483","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/comments?post=48483"}],"version-history":[{"count":0,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/pages\/48483\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/media\/44498"}],"wp:attachment":[{"href":"https:\/\/techmaster.com.vn\/en\/wp-json\/wp\/v2\/media?parent=48483"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}